Backup & Load Settings - YASKAWA MOTOMAN DX100 Instruction Manual

Programming pendant cheat sheet
Hide thumbs Also See for MOTOMAN DX100:
Table of Contents

Advertisement

166465-1CD
Auto-Axcess DI/E Digital
3.5.10 Backup & Load Settings
3
Equipment Description
3.5 Miller-Motoman Pendant Interface (HMI) Software
1. Operator Mode Change: This button toggles the HMI between the
Operator/Manager Mode - The default setting is "Operator Mode". In
the Operator Mode, all the screens can be viewed, but the "Save"
buttons are disabled and no data can be changed.
• Pressing the Manager Mode button will prompt a dialog box to
appear.
• Enter the managers password (default is 99999999 [eight 9's]).
• Confirm change by selecting the yes box.
2. Editing Functions: These statements allow various editing functions
to be activated while in Operator Mode. To activate any combination of
the Editing Functions, go to "Management Mode" and select the
desired boxes.
3. Lock front panel on welder power supplies: In Management Mode,
selecting this box will lock the front panel of all Miller Auto-Axcess DI/E
Digital connected to the system. The "Lock" symbol on the Auto-
Axcess DI/E Digital will be lit when this feature is activated. Users will
not be able to make changes from the front panel.
4. Select welder communication mode: The Miller Auto-Axcess DI/E
DigitalI has 3 different levels of communication and is selected from
this box:
• Shared Control (the default setting) - This is the preferred
setting, it allows both the DX100 and the Miller Auto-Axcess DI/E
Digital to control various features.
• Robot Control - This setting allows only the DX100 to control
various weld settings, such as pre-flow, post-flow, etc. These
functions will be locked out from the HMI.
• Power Source Control - This setting shifts all control to the
power source. Only arc on and arc off are controlled by the
Robot.
5. Password & ReType Password: To change the password select
Manager Mode and create a new password in the Password window
and confirm it in the ReType Password window. If the password does
not need to be changed leave the windows blank.
The Backup & Load Settings Screen has several functions; backing up a
welder HMI Settings, copying a configuration to another welder, or
copying or resetting the 'INI' file. This function only serves the robot HMI.
The data is not a replacement for the Miller File Manager PDA software
that saves data directly from the welder.
A CompactFlash memory card or USB must be installed in
NOTE
the programming pendant in order to backup the welder.