228 Resistor braking
Drive type
U
= 690 V
N
ACS880-07-0061A-7
ACS880-07-0084A-7
ACS880-07-0098A-7
ACS880-07-0119A-7
ACS880-07-0142A-7
ACS880-07-0174A-7
ACS880-07-0210A-7
ACS880-07-0271A-7
P
The internal brake chopper will withstand this continuous braking power.
brcont
R
The minimum allowed resistance value of the brake resistor
min
R
Resistance value for the listed resistor assembly
E
Short energy pulse that the resistor assembly withstands every 400 seconds
R
P
Continuous power (heat) dissipation of the resistor when placed correctly
Rcont
The ratings apply at an ambient temperature of 40 °C (104 °F)

Degree of protection of SAFUR resistors

The degree of protection of SAFUR resistors is IP00.

Terminals and cable lead-through data

See section
Terminal and lead-through data for the power cables
Internal brake
Example brake resistor(s)
chopper
P
R
Type
brcont
min
kW
ohm
55
13
65
13
90
8
110
8
132
6
160
6
200
4
250
4
R
ohm
SACE15RE13
SACE15RE13
SAFUR90F575
SAFUR90F575
SAFUR80F500
SAFUR80F500
SAFUR125F500
SAFUR125F500
E
P
R
Rcont
kJ
kW
13
435
2
13
435
2
8
1800
4.5
8
1800
4.5
6
2400
6
6
2400
6
4
3600
9
4
3600
9
3AXD00000588487
on page 184.