8 Troubleshooting
ALARM 38, Internal fault
It may be necessary to contact your Danfoss supplier. Some typical alarm
messages:
0
Serial port cannot be initialized. Serious hardware failure
256-258 Power EEPROM data is defect or too old
512
Control board EEPROM data is defect or too old
513
Communication timeout reading EEPROM data
514
Communication timeout reading EEPROM data
515
Application Orientated Control cannot recognize the EE-
PROM data
516
Cannot write to the EEPROM because a write command
is on progress
517
Write command is under timeout
518
Failure in the EEPROM
519
Missing or invalid Barcode data in EEPROM
783
Parameter value outside of min/max limits
1024-127
A CAN message that has to be sent, couldn't be sent
9
1281
Digital Signal Processor flash timeout
1282
Power micro software version mismatch
1283
Power EEPROM data version mismatch
1284
Cannot read Digital Signal Processor software version
1299
Option SW in slot A is too old
1300
Option SW in slot B is too old
1301
Option SW in slot C0 is too old
1302
Option SW in slot C1 is too old
1315
Option SW in slot A is not supported (not allowed)
1316
Option SW in slot B is not supported (not allowed)
1317
Option SW in slot C0 is not supported (not allowed)
1318
Option SW in slot C1 is not supported (not allowed)
1379
Option A did not respond when calculating Platform Ver-
8
sion.
1380
Option B did not respond when calculating Platform Ver-
sion.
1381
Option C0 did not respond when calculating Platform
Version.
1382
Option C1 did not respond when calculating Platform
Version.
1536
An exception in the Application Orientated Control is
registered. Debug information written in LCP
1792
DSP watchdog is active. Debugging of power part data
motor orientated control data not transferred correctly
2049
Power data restarted
2064-207
H081x: option in slot x has restarted
2
8-8
2080-2088 H082x: option in slot x has issued a power-up wait
2096-2104 H083x: option in slot x has issued a legal power-up
wait
2304
Could not read any data from power EEPROM
2305
Missing SW version from power unit
2314
Missing power unit data from power unit
2315
Missing SW version from power unit
2316
Missing io_statepage from power unit
2324
Power card configuration is determined to be incorrect
at power-up
2330
Power size information between the power cards does
not match
2561
No communication from DSP to ATACD
2562
No communication from ATACD to DSP (state running)
2816
Stack overflow Control board module
2817
Scheduler slow tasks
2818
Fast tasks
2819
Parameter thread
2820
LCP Stack overflow
2821
Serial port overflow
2822
USB port overflow
2836
cfListMempool to small
3072-5122 Parameter value is outside its limits
5123
Option in slot A: Hardware incompatible with control
board hardware
5124
Option in slot B: Hardware incompatible with control
board hardware
5125
Option in slot C0: Hardware incompatible with control
board hardware
5126
Option in slot C1: Hardware incompatible with control
board hardware
5376-6231 Out of memory
ALARM 39, Heatsink sensor
No feedback from the heatsink temperature sensor.
The signal from the IGBT thermal sensor is not available on the power
card. The problem could be on the power card, on the gate drive card,
or the ribbon cable between the power card and gate drive card.
WARNING 40, Overload of Digital Output Terminal 27
Check the load connected to terminal 27 or remove short-circuit connec-
tion. Check par. 5-00
WARNING 41, Overload of Digital Output Terminal 29
Check the load connected to terminal 29 or remove short-circuit connec-
tion. Check par. 5-00
WARNING 42, Overload of Digital Output on X30/6 or Overload
of Digital Output on X30/7
For X30/6, check the load connected to X30/6 or remove short-circuit
connection. Check par. 5-32
For X30/7, check the load connected to X30/7 or remove short-circuit
connection. Check par. 5-33
ALARM 46, Power card supply
The supply on the power card is out of range.
There are three power supplies generated by the switch mode power
supply (SMPS) on the power card: 24 V, 5 V, +/-18 V. When powered
with 24 VDC with the MCB 107 option, only the 24 V and 5 V supplies are
monitored. When powered with three-phase AC line voltage, all three
supplied are monitored.
WARNING 47, 24 V supply low
The 24 V DC is measured on the control card. The external V DC backup
power supply may be overloaded, otherwise contact your Danfoss sup-
plier.
MG.11.AB.22 - VLT
®
is a registered Danfoss trademark
VLT
®
HVAC Drive Instruction Manual
Digital I/O Mode
Terminal 27 Mode
and par. 5-01
Digital I/O Mode
Terminal 29 Mode
and par. 5-02
Term X30/6 Digi Out (MCB 101)
Term X30/7 Digi Out (MCB 101)
.
.
.
.