Load / Motor; Brakes - Danfoss VLT HVACDrive Instruction Manual

Table of Contents

Advertisement

7 How to Program the Adjustable Frequency
Drive

7.3.3 1-** Load / Motor

Par.
Parameter description
No. #
1-0* General Settings
1-00
Configuration Mode
1-03
Torque Characteristics
1-2* Motor Data
1-20
Motor Power [kW]
1-21
Motor Power [HP]
1-22
Motor Voltage
1-23
Motor Frequency
1-24
Motor Current
1-25
Motor Nominal Speed
1-28
Motor Rotation Check
1-29
Automatic Motor Adaptation (AMA)
1-3* Addl. Motor Data
1-30
Stator Resistance (Rs)
1-31
Rotor Resistance (Rr)
1-35
Main Reactance (Xh)
1-36
Iron Loss Resistance (Rfe)
1-39
Motor Poles
1-5* Load-Indep. Setting
1-50
Motor Magnetization at Zero Speed
1-51
Min Speed Normal Magnetizing [RPM]
1-52
Min Speed Normal Magnetizing [Hz]
1-6* Load-Depend. Settg.
7
1-60
Low Speed Load Compensation
1-61
High Speed Load Compensation
1-62
Slip Compensation
1-63
Slip Compensation Time Constant
1-64
Resonance Dampening
1-65
Resonance Dampening Time Constant
1-7* Start Adjustments
1-71
Start Delay
1-73
Flying Start
1-8* Stop Adjustments
1-80
Function at Stop
1-81
Min Speed for Function at Stop [RPM]
1-82
Min Speed for Function at Stop [Hz]
1-86
Trip Speed Low [RPM]
1-87
Trip Speed Low [Hz]
1-9* Motor Temperature
1-90
Motor Thermal Protection
1-91
Motor External Fan
1-93
Thermistor Source

7.3.4 2-** Brakes

Par.
Parameter description
No. #
2-0* DC Brake
2-00
DC Hold/Preheat Current
2-01
DC Brake Current
2-02
DC Braking Time
2-03
DC Brake Cut-in Speed [RPM]
2-04
DC Brake Cut-in Speed [Hz]
2-1* Brake Energy Funct.
2-10
Brake Function
2-11
Brake Resistor (ohm)
2-12
Brake Power Limit (kW)
2-13
Brake Power Monitoring
2-15
Brake Check
2-16
AC Brake Max. Current
2-17
Over-voltage Control
7-54
Default value
null
[3] Auto Energy Optim. VT
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
[0] OFF
[0] Off
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
100 %
ExpressionLimit
ExpressionLimit
100 %
100 %
0 %
ExpressionLimit
100 %
5 ms
0.0 s
[0] Disabled
[0] Coast
ExpressionLimit
ExpressionLimit
0 RPM
0.0 Hz
[4] ETR trip 1
[0] No
[0] None
Default value
50 %
50 %
10.0 s
ExpressionLimit
ExpressionLimit
[0] Off
ExpressionLimit
ExpressionLimit
[0] Off
[0] Off
100.0 %
[2] Enabled
MG.11.AB.22 - VLT
®
is a registered Danfoss trademark
VLT
®
HVAC Drive Instruction Manual
4-set-up
Change dur-
Conver-
ing operation
sion index
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
FALSE
1
All set-ups
FALSE
-2
All set-ups
FALSE
0
All set-ups
FALSE
0
All set-ups
FALSE
-2
All set-ups
FALSE
67
All set-ups
FALSE
-
All set-ups
FALSE
-
All set-ups
FALSE
-4
All set-ups
FALSE
-4
All set-ups
FALSE
-4
All set-ups
FALSE
-3
All set-ups
FALSE
0
All set-ups
TRUE
0
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-2
All set-ups
TRUE
0
All set-ups
TRUE
-3
All set-ups
TRUE
-1
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-
4-set-up
Change dur-
Conver-
ing operation
sion index
All set-ups
TRUE
0
All set-ups
TRUE
0
All set-ups
TRUE
-1
All set-ups
TRUE
67
All set-ups
TRUE
-1
All set-ups
TRUE
-
All set-ups
TRUE
-2
All set-ups
TRUE
0
All set-ups
TRUE
-
All set-ups
TRUE
-
All set-ups
TRUE
-1
All set-ups
TRUE
-
Type
Uint8
Uint8
Uint32
Uint32
Uint16
Uint16
Uint32
Uint16
Uint8
Uint8
Uint32
Uint32
Uint32
Uint32
Uint8
Uint16
Uint16
Uint16
Int16
Int16
Int16
Uint16
Uint16
Uint8
Uint16
Uint8
Uint8
Uint16
Uint16
Uint16
Uint16
Uint8
Uint16
Uint8
Type
Uint8
Uint16
Uint16
Uint16
Uint16
Uint8
Uint32
Uint32
Uint8
Uint8
Uint32
Uint8