Special Functions - Danfoss VLT HVACDrive Instruction Manual

Table of Contents

Advertisement

VLT
®
HVAC Drive Instruction Manual

7.3.14 14-** Special Functions

Par.
Parameter description
No. #
14-0* Inverter Switching
14-00
Switching Pattern
14-01
Switching Frequency
14-03
Overmodulation
14-04
PWM Random
14-1* Mains On/Off
14-10
Mains Failure
14-11
Mains Voltage at Mains Fault
14-12
Function at Mains Imbalance
14-2* Reset Functions
14-20
Reset Mode
14-21
Automatic Restart Time
14-22
Operation Mode
14-23
Typecode Setting
14-25
Trip Delay at Torque Limit
14-26
Trip Delay at Inverter Fault
14-28
Production Settings
14-29
Service Code
14-3* Current Limit Ctrl.
14-30
Current Lim Cont, Proportional Gain
14-31
Current Lim Contr, Integration Time
14-32
Current Lim Ctrl, Filter Time
14-4* Energy Optimizing
14-40
VT Level
14-41
AEO Minimum Magnetization
14-42
Minimum AEO Frequency
14-43
Motor Cos-Phi
14-5* Environment
14-50
RFI 1
14-52
Fan Control
14-53
Fan Monitor
14-55
Output Filter
14-59
Actual Number of Inverter Units
14-6* Auto Derate
14-60
Function at Overtemperature
14-61
Function at Inverter Overload
14-62
Inv. Overload Derate Current
Default value
null
null
[1] On
[0] Off
[0] No function
ExpressionLimit
[0] Trip
null
10 s
[0] Normal operation
null
60 s
ExpressionLimit
[0] No action
0 N/A
100 %
0.020 s
26.0 ms
66 %
ExpressionLimit
10 Hz
ExpressionLimit
[1] On
[0] Auto
[1] Warning
[0] No Filter
ExpressionLimit
[0] Trip
[0] Trip
95 %
MG.11.AB.22 - VLT
®
is a registered Danfoss trademark
7 How to Program the Adjustable Frequency
4-set-up
Change dur-
ing operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
2 set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
FALSE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
FALSE
1 set-up
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Drive
Conver-
Type
sion index
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint16
-
Uint8
-
Uint8
0
Uint16
-
Uint8
-
Uint8
0
Uint8
0
Uint8
-
Uint8
0
Int32
0
Uint16
-3
Uint16
-4
Uint16
7
0
Uint8
0
Uint8
0
Uint8
-2
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint8
-
Uint8
-
Uint8
0
Uint16
7-61

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vlt hvac drive fc 100 series

Table of Contents