7 How to Program the Adjustable Frequency
Drive
[1669]
Pulse Output #27 [Hz]
[1670]
Pulse Output #29 [Hz]
[1671]
Relay Output [bin]
[1672]
Counter A
[1673]
Counter B
[1675]
Analog In X30/11
[1676]
Analog In X30/12
[1677]
Analog Out X30/8 [mA]
[1680]
Fieldbus CTW 1
[1682]
Fieldbus REF 1
[1684]
Comm. Option Status
[1685]
FC Port CTW 1
7
[1686]
FC Port REF 1
[1690]
Alarm Word
[1691]
Alarm word 2
[1692]
Warning Word
[1693]
Warning word 2
[1694]
Ext. Status Word
[1695]
Ext. Status Word 2
[1696]
Maintenance Word
[1830]
Analog Input X42/1
[1831]
Analog Input X42/3
[1832]
Analog Input X42/5
[1833]
Analog Out X42/7 [V]
[1834]
Analog Out X42/9 [V]
[1835]
Analog Out X42/11 [V]
[1850]
Sensorless Readout [unit]
[2117]
Ext. 1 Reference [Unit]
[2118]
Ext. 1 Feedback [Unit]
[2119]
Ext. 1 Output [%]
[2137]
Ext. 2 Reference [Unit]
[2138]
Ext. 2 Feedback [Unit]
[2139]
Ext. 2 Output [%]
7-10
Actual value of pulses applied to terminal 27 in digital output mode.
Actual value of pulses applied to terminal 29 in digital output mode.
View the setting of all relays.
View the present value of Counter A.
View the present value of Counter B.
Actual value of the signal on input X30/11 (General Purpose I/O Card. Option)
Actual value of the signal on input X30/12 (General Purpose I/O Card. Optional)
Actual value at output X30/8 (General Purpose I/O Card. Optional) Use Par. 6-60 to select the var-
iable to be shown.
Control word (CTW) received from the bus master.
Main reference value sent with control word via the serial communications network, e.g., from the
BMS, PLC or other master controller.
Extended serial communication option status word.
Control word (CTW) received from the bus master.
Status word (STW) sent to the bus master.
One or more alarms in a Hex code (used for serial communications)
One or more alarms in a Hex code (used for serial communications)
One or more warnings in a Hex code (used for serial communications)
One or more warnings in a Hex code (used for serial communications)
One or more status conditions in a Hex code (used for serial communications)
One or more status conditions in a Hex code (used for serial communications)
The bits reflect the status for the programmed preventive maintenance events in parameter group
23-1*
Shows the value of the signal applied to terminal X42/1 on the Analog I/O card.
Shows the value of the signal applied to terminal X42/3 on the Analog I/O card.
Shows the value of the signal applied to terminal X42/5 on the Analog I/O card.
Shows the value of the signal applied to terminal X42/7 on the Analog I/O card.
Shows the value of the signal applied to terminal X42/9 on the Analog I/O card.
Shows the value of the signal applied to terminal X42/11 on the Analog I/O card.
The value of the reference for extended Closed-loop Controller 1
The value of the feedback signal for extended Closed-loop Controller 1
The value of the output from extended Closed-loop Controller 1
The value of the reference for extended Closed-loop Controller 2
The value of the feedback signal for extended Closed-loop Controller 2
The value of the output from extended Closed-loop Controller 2
MG.11.AB.22 - VLT
®