Utility mode
7
Press the [Start] key.
–
Only paper loaded into the bypass tray can be used.
A test pattern is printed.
8
Check that the distance from the starting print position of the test
pattern to the edge of the paper (a) is 4.2 mm.
–
If the distance is less than 4.2 mm, touch [+] to increase the
adjustment (between 0.2 mm and 3.0 mm).
–
If the distance is more than 4.2 mm, touch [-] to reduce the
adjustment (between -0.2 mm and -3.0 mm).
–
Each time [+] or [-] is touched, the value is increased or decreased
by one increment.
9
Press the [Start] key.
The adjusted test pattern is printed.
10
Check the distance from the starting print position of the test pattern
to the edge of the paper.
–
Check that the width has been adjusted to 4.2 mm.
–
If more adjustment is necessary, repeat steps 8 and 9.
–
To adjust the print position for a different type of paper, return to
step 6.
11
Touch [OK].
–
To cancel the setting and select the default, press the [Reset] key.
The print position is adjusted.
C451
a: 4.2 mm
11
a
11-63