Daikin RTSQ20PY1 Service Manual page 48

Vrv iii-c r-410a heat pump 50hz
Hide thumbs Also See for RTSQ20PY1:
Table of Contents

Advertisement

Specifications
1-1 TECHNICAL SPECIFICATIONS
Capacity
Cooling
Heating
Power Input
Cooling
Heating
Casing
Material
Dimensions
Unit
Height
Width
Depth
Weight
Unit
Heat
Dimensions Nr of Rows
Exchanger
Fin Pitch
Face Area
Nr of Stages
Fan
Type
Airflow Rate Cooling
High high
High
Low
Fan
External
High
static
Standard
pressure
Low
Motor
Output
(high)
Drive
Piping
Liquid
Type
connections
(OD)
Diameter
Gas
Type
Diameter
Drain
Diameter
Refrigerant control
Temperature control
Safety devices
Standard Accessories
Notes
37
FXMQ63PVE
kW
7.1
kW
8.0
kW
0.230
kW
0.218
mm
mm
1,000
mm
kg
36
mm
0.249
m³/min
19.5
m³/min
17.5
m³/min
16
Pa
200
Pa
Pa
50
W
350
mm
9.52
mm
15.9
mm
Nominal cooling capacities are based on following conditions: return air temperature: 27°CDB/19°CWB; outdoor
temperature: 35°CDB; standard external static pressure: 100Pa; equivalent refrigerant piping: 7.5m (horizontal)
Nominal heating capacities are based on following conditions: return air temperature: 20°CDB; outdoor temperature:
7°CDB/6°CWB; standard external static pressure: 100Pa; equivalent refrigerant piping: 7.5m (horizontal)
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
External static pressure is changeable in 7, 13, 14, 10 stages within the ( ) range by the remote control.
Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its colorimetric
FXMQ80PVE
FXMQ100PVE
9.0
11.2
10.0
12.5
0.298
0.376
0.286
0.364
Galvanised steel plate
300
1,000
1,400
700
36
46
3
1.75
0.249
0.383
16
Sirocco fan
25
32
22.5
27
20
23
200
200
100
50
50
350
350
Direct drive
Flare connection
9.52
9.52
Flare connection
15.9
15.9
VP25 (I.D. 32/O.D. 25)
Electronic expansion valve
Microprocessor thermostat for cooling and heating
Fuse
Fan driver overload protector
Operation manual
Installation manual
Drain hose
Sealing pads
Clamps
Washer
Screws
Insulation for fitting
Clamp metal
Air discharge flange
Air suction flange
method (gravity method) 50% or more.
SiBE31-801_C
FXMQ125PVE
FXMQ140PVE
14.0
16.0
16.0
18.0
0.461
0.461
0.449
0.449
1,400
1,400
46
47
1.5
0.383
0.383
39
46
33
39
28
32
200
140
50
50
350
350
9.52
9.52
15.9
15.9
Specifications

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rtsq16py1Rtsq14py1Rtsq10py1

Table of Contents