Specifications
Concealed Ceiling Unit
1-1 TECHNICAL SPECIFICATIONS
Piping
Liquid
Type
connections
(OD)
Diameter
Gas
Type
Diameter
Drain
Diameter
Heat Insulation
Decoration
Model
Panel
Colour
Dimensions Height
Width
Depth
Weight
Drain-up Height
Air Filter
Refrigerant control
Safety devices
Notes
1-2 ELECTRICAL SPECIFICATIONS
Power
Name
Supply
Frequency
Voltage
Current
Minimum circuit amps
(MCA)
Maximum fuse amps
(MFA)
Voltage
Minimum
range
Maximum
Notes
1-1 ELECTRICAL SPECIFICATIONS
Power
Name
Supply
Frequency
Voltage
Current
Minimum circuit amps
(MCA)
Maximum fuse amps
(MFA)
Voltage
Minimum
range
Maximum
Notes
35
FXSQ63P7VEB
mm
mm
mm
BYBS71DJW1
mm
mm
1,100
mm
kg
4.5
mm
Nominal cooling capacities are based on : indoor temperature : 27°CDB, 19°CWB, outdoor temperature : 35°CDB,
Nominal heating capacities are based on : indoor temperature : 20°CDB, outdoor temperature : 7°CDB, 6°CWB,
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
The sound pressure values are mentioned for a unit installed with rear suction
FXSQ20P7VEB
FXSQ25P7VEB
Hz
V
A
0.4
A
V
V
Voltage range : units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or
Maximum allowable voltage range variation between phases is 2%.
FXSQ63P7VEB
Hz
V
A
1.1
A
V
V
Voltage range : units are suitable for use on electrical systems where voltage supplied to unit terminals is not below or
Maximum allowable voltage range variation between phases is 2%.
FXSQ80P7VEB
FXSQ100P7VEB
Flare connection
9.52
Flare connection
15.9
VP25 (O.D. 32 / I.D. 25)
Both liquid and gas pipes
BYBS71DJW1
BYBS125DJW1
White (10Y9/0,5)
55
1,100
500
4.5
625
Resin net with mold resistance
Electronic expansion valve
PCB fuse
PCB fuse (fan driver)
Drain pump fuse
equivalent refrigerant piping : 7.5m, level difference : 0m.
equivalent refrigerant piping : 7.5m, level difference : 0m.
FXSQ32P7VEB
VE
50
220-240
0.4
0.4
16
-10%
+10%
above listed range limits.
Select wire size based on the MCA
Instead of a fuse, use a circuit breaker
FXSQ80P7VEB
FXSQ100P7VEB
VE
50
220-240
1.3
16
-10%
+10%
above listed range limits.
Select wire size based on the MCA
Instead of a fuse, use a circuit breaker
SiBE31-801_C
FXSQ125P7VEB
BYBS125DJW1
1,500
1,500
6.5
6.5
FXSQ40P7VEB
FXSQ50P7VEB
1.2
1.2
FXSQ125P7VEB
1.6
2.1
Specifications