Statistics Control; Printhead Reset - Printronix T2N series User Manual

Thermal label printers
Hide thumbs Also See for T2N series:
Table of Contents

Advertisement

Max # of Files in DRAM
Allows the user to select the maximum number of files to be allocated in the DRAM File System.
The choices are 128, 256, 384, and 512.
The factory default is 256.
Page Memory
Emulations use page memory to create images and send them to the engine. The amount of memory
allocated can have an effect on the maximum Label Length setting in the Media/Sensor tab and print
throughput. This value may increase if users need long labels or reduced if users are printing small
labels (less than 2 inches in length) and want to use the extra memory elsewhere. Users can
experiment with this value to see how it affects performance.
The range is 300 KB to 4600 KB in increments of 300 KB with the exception of 2200 KB and
4600 KB. The factory default is 2200 KB. The page memory size affects the maximum label length.
The maximum label length with page memory of 2200 KB for 300 dpi printers is 48 inches. To print
labels longer than 48 inches on a 300 dpi printer, change the page memory size.
Setting the Factory Configuration
Upon clicking the "Factory Set" button, a window opens prompting the user to confirm the operation.
IMPORTANT: Be aware that changing File System and Memory settings can affect system
performance, overwrite the Factory Configuration, and reboot the printer.

Statistics Control

This section is used to reset counters in the engine.

PrintHead Reset

Click the "PrintHead Reset" button each time a printhead is replaced. This keeps an accurate account
of how much of the printhead has been used.
Usage
The printhead usage value displays in inches only and can be reset by using the "PrintHead Reset"
option within Statistics Control in Advanced Setup. When a new printhead is installed, reset the
printhead for accuracy.
111

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents