Printronix T2N series User Manual page 95

Thermal label printers
Hide thumbs Also See for T2N series:
Table of Contents

Advertisement

IMPORTANT: Two options within the Media/Sensor tab can force Auto Calibration:
(1) Power-Up Action = Auto Calibrate
(2) Head Auto Cal = Enable
When option (1) is set, the Auto Calibration procedure happens immediately upon power-up.
When option (2) is set, Auto Calibration happens after the printhead is properly latched and
the Feed key is pressed.
Manual Setup
Option
Sensor Intensity
Reading Intensity
Threshold value
Current Reading
Manual Calibration is for advanced users only with special
media. The operation calibrates the sensors only. When the
Sensor Calibration window opens, the values for "Sensor
Intensity", "Reading Intensity", and "Threshold Value" are set to
their current values in the printer. The "Current Reading" field is
a read-only field monitored by the printer for comparison with
the set "Reading Intensity" value.
Defaults and explanations for these fields are shown in the table
below with processes for each Media type.
Default
Range
Gap 3
Gap 0-7
Mark 2
Mark 0-3
Gap 3
Gap 0-7
Mark 2
Mark 0-3
512
1023
N/A
0-1023
Description
This value is to set the emitting intensity of the
gap sensor or black mark sensor.
The emitting intensity for the current reading.
The reference value to determine whether the
sensor is seeing the gap/label or black
mark/non-black mark.
The receiving sensor signal strength. This is
read only.
95