WARNING
During maintenance activities, remain with the machine.
When de-scaling, always follow the instructions for the de-scaling agent used.
It is advisable to wear safety glasses and protective gloves when de-scaling.
After de-scaling, let the machine complete at least three cycles.
Wash your hands thoroughly after de-scaling.
The machine must never be immersed in or sprayed with water.
WARNING
Pressurised hot water! Do not remove components like valves, couplings,
plugs and hoses before depressurise the boiler system.
6.5 De-scaling instructions
Animo supplies a descaling agent in the following quantities:
Descaling agent 48x 50 g sachets art. no. 49007
Descaling agent 1 kg can art. no. 00009
Time required, agents and tools:
Time: approx. 45 min.
Animo Descaling Agent
Drip tray of approx. 1.5 L
Crosshead screwdriver
Service kit [art. no. 1001365]
(measurement beaker, hose, manometer)
Descaling
1. Start the descaling programme. service menu /
2.15 Descale and follow the instructions on the display.
2. Close the door and place an empty bucket under
both outlets.
Descaling
Place empty container
Press enter (v)
Stop? Press x
3. Prepare 2 litre de-scaler solution. Read the warnings
and instructions for the Animo de-scaling agent first.
2015/09 Rev. 1.2
Descaling
Boiler
depressurising
moment please
73
Min. 1,5 L
2 Ltr.