OptiBean /OptiBean XL
WARNING
•
During maintenance activities, remain with the machine.
•
When de-scaling, always follow the instructions for the de-scaling agent used.
•
It is advisable to wear safety glasses and protective gloves when de-scaling.
•
After de-scaling, let the machine complete at least three cycles.
•
Wash your hands thoroughly after de-scaling.
•
The machine must never be immersed in or sprayed with water.
WARNING
•
Pressurised hot water! Do not remove components like valves, couplings,
plugs and hoses before depressurise the boiler system.
6.5 De-scaling instructions
Animo supplies a descaling agent in the following quantities:
•
Descaling agent 48x 50 g sachets art. no. 49007
•
Descaling agent 1 kg can art. no. 00009
Time required, agents and tools:
•
Time: approx. 45 min.
•
Animo Descaling Agent
•
Drip tray of approx. 1.5 L
•
Crosshead screwdriver
•
Service kit [art. no. 1001365]
(measurement beaker, hose, manometer)
Descaling
1. Start the descaling programme. service menu /
2.15 Descale and follow the instructions on the display.
2. Close the door and place an empty bucket under
both outlets.
Descaling
Place empty container
Press enter (v)
Stop? Press x
3. Prepare 2 litre de-scaler solution. Read the warnings
and instructions for the Animo de-scaling agent first.
2015/09 Rev. 1.2
Descaling
Boiler
depressurising
moment please
73
Min. 1,5 L
2 Ltr.
EN
Need help?
Do you have a question about the OptiBean and is the answer not in the manual?