Autoimage; Warning Messages - Barco SIM 5W User Manual

Table of Contents

Advertisement

7.11.6.1 AutoImage

What can be done ?
AutoImage can be disabled. In case of a new (unknow) source, no automatic file selection will be done. Instead, a more or less
suited file will be selected, resulting in a misaligned image. Image settings must be done manually (edit image file).
How to enable/disable AutoImage ?
1. Press MENU to activate the Tool bar
2. Press → to select the Service item
3. Press ↓ to Pull down the menu
4. Use ↑ or ↓ to select Operation options
5. Press → to pull down the menu
6. Press ↓ to select Autoimage
7. Press → to pull down the menu
8. Use ↑ or ↓ to select On/Off
9. Press ENTER
Image 7-245
A white bullet shows the active setting

7.11.6.2 Warning messages

What can be done?
It is possible to block some Warning messages during projector runtime. The table below gives an overview of those messages that
can be suppressed during runtime.
Warning message
NO SIGNAL
Lamp error icon
Lamp runtime warning
Lamp runtime exceeded
Desktop resolution not valid
Wait box
How to enable/disable Warning Messages?
1. Press MENU to activate the Tool bar
R59770324 SIM 5W 22/12/2011
Downloaded From projector-manual.com Barco Manuals
Sim 5W
x
x
x
x
x
For safety reasons, the warning messages Lamp runtime warning and Lamp runtime exceeded will always
pop up during start-up of the projector. They can only be suppressed during projector runtime.
Galaxy NH-12
Description
Galaxy NW-12
Galaxy NW-7
x
In case no incoming Sync is detected
In case of an actual lamp or LPS problem
x
Max lamp runtime almost reached
x
Max lamp runtime exceeded
x
Desktop input signal resolution is out of
specification.
x
An hourglass icon that is displayed during
processing