Clear Lamp Error - Barco SIM 5W User Manual

Table of Contents

Advertisement

How to reset the lamp runtime?
1. Press MENU to activate the tool bar
2. Press → to select the Lamps item
3. Press ↓ to pull down the Lamps menu
4. Use ↑ or ↓ to select Reset Runtime
5. Press → to open the Reset Runtime menu
6. Use ↑ or ↓ to select the lamps to be reset
Image 7-138
7. Press ENTER
A dialog box is displayed
Image 7-139
8. Use ←or →, the numeric keys on the remote, or the keypad to change the serial number of the lamp (serial number 0000000 will
not be accepted).
9. Select Accept to reset the lamp runtime and to confirm the serial number of the new lamp
7.7.7

Clear lamp error

Lamp error
When a failure of one of the lamps has occurred, a lamp logo is displayed in the left corner of the screen. This logo will thus always
inform the user on a previous lamp error.
Once the error has been solved or/and the lamp has been replaced one can remove (clear) the lamp error.
If the error has been cleared without solving the lamp problem the logo will be shown at next lamp startup (projector startup for
example)
R59770324 SIM 5W 22/12/2011
Downloaded From projector-manual.com Barco Manuals
A lamp failing to startup will be noticed by a low light output of the projector since the projector goes in single
lamp mode.
In case of a lamp error contact the local Barco authorized technician
7. Advanced