Bronpi hydro series Installation, Operating And Servicing Instruction page 49

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 28
TIME
0.0"
POWER
LOAD
OPERATIONAL
MENU
D72
9.4.1
THERMO STOVE OR INSERT IGNITION
To ignite the thermo-stove or insert, press button no. 3 for a few seconds. The
display will show the ignition state as follows (see drawing D76).
The maximum length of the ignition phase is 25 minutes. After this time, if there is
no visible flame, the thermo-stove will automatically go into an alarm state and the
control will show the message "Ignition Failure."
9.4.2
THERMO STOVE OR INSERT IN OPERATION
Once the set smoke temperature has been reached, the thermo-stove or insert is
working. Before this, it will be in the state "Fire Present" and this will last just a few
minutes before considering the equipment totally ignited.
At that moment, the display will show the message "Work." After this, our thermo-
stove or insert will be working normally (see drawing D77).
The display shows the room temperature and the temperature reached by the circuit
water.
9.4.3
CHANGE OF THE SET-POINT ROOM TEMPERATURE
In order to modify the setting room temperature, please press button 4 and then
buttons 1 and 2 to increase or decrease it respectively (see drawing D78).
If we want the thermo-stove or insert to be controlled by an external thermostat,
you should contact your Bronpi Calefacción S.L. authorised technical service
engineerbecause will be necessary to activate this external thermostat in the
9.4.4
CHANGE WATER TEMPERATURE SET
In order to modify the set water temperature, please press button 6 and then buttons
1 and 2 to increase or decrease it respectively (see drawing D80).
9.4.5
ROOM OR WATER TEMPERATURE REACHES TEMPERATURE FIXED
BY THE USER
When the room temperature reaches the value set by the user or the water
temperature reaches the desired value, the thermo-stove or insert will automatically
operate at one lower power, it means that modulates in power. (See drawing D81).
Remember that if it is activated "stand-by mode", when the ambient temperature
reaches the value set by the user plus a differential (2ºC) the thermo-stove or insert
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
WATER
25.0º C
P-2
1.6 b
T-SCHEDA
PRESSURE
PRES-H2O
TEXT
MENU
D73
technical menu. Connection of a volt free signal
from a room thermostat or heating controller to
the rear of the thermo-stove, and the correct
software parameters is all that is required (see
drawing D79). You can find Bronpi external
thermostat at the same Bronpi distributor where you bought your thermo-
stove.
Remember that if you want your thermo-stove or insert to start and stop
according to the demand of the external thermostat you must have the menu
"stand-by mode" activated (on). Otherwise, it will modulate when the water
D79
temperature or external thermostat set-point
value is reached (the first one which reaches this
temperature).
TIME-OUT
10"
00"
TIME
RAL
CLEANING
STBY
MODE
STAND BY
MENU
14:24
21º C
OFF
MENU
14:24
21º C
WORKING
MENU
65º C
SET TEMPER
WATER
MENU
48
SMOKE
119º
1900
SPEED
60
EXTR.
03
STATE 5
STOVE
STATE
MENU
D74
14:24
23ºC
21º C
23ºC
IGNITION
MENU
D75
21º C
68ºC
SET TEMPER
ROOM
MENU
D77
16:40
27º C
63ºC
WORKING
MODULATE
MENU
D80
HYDRO SERIES RADIOFREQUENCY
D76
D78
D81

Advertisement

Table of Contents
loading

Table of Contents