Bronpi hydro series Installation, Operating And Servicing Instruction page 45

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 28
9.3
MENU OPTION
By pressing button nº 7 of display we can access into the MENU. It is divided into different sections and levels that allow to access to the
stove configuration and programming.
The access to the technical menu of the thermo-stove or insert is protected by a password. These parameters should be modified only by an
authorised technician. (The changes in these parameters could cause a wrong running in the insert or thermo-stove and the subsequent lost
of its warranty.)
9.3.1
USER MENU
The following table briefly describes the menu structure in the thermo-stove or insert. In the attached table, only the options available to the
user are specified.
MENU
01 – Choose season
02 - Clock adjustments
03 - Programme setting
04 - Select Language
05- Stand-by Mode
06 - Sound mode
07 - Initial load
08- Choose probe
09 - Stove State
9.3.2
MENU 1. SUMMER/WINTER MODE
This menu has two options: "SUMMER" and "WINTER."
In the event of selecting the "winter" mode we need to take into account that the insert or thermo-
stove will allow us to use simultaneously the heating system together with the SHW (Sanitary Hot
Water) heating system. We always need to give priority to the SHW heating system and it needs to
be directly installed to our insert or thermo-stove. In the event of having connected the equipment
only with our heating circuit, the insert or thermo-stove will work, anyway, in the same way and it will regulate
the performance only throughout the values that we want. This working mode is advisable during the coldest
periods. In the event of selecting the "summer" mode, a proper operation is only guaranteed when we have
installed an SHW heating system. This is due to the fact that during the summer season the boiler considers
unnecessary the use of heating systems, so it will only work in the case of demanding hot sanitary water. When
our installation does not have the SHW heating system it is advisable to select the "winter" mode. (see drawing
D49).
9.3.3
MENU 2. CLOCK
It sets up the time and date. To set the clock up you have to move by the different submenus and introduce the
data, changing values with buttons 1 and 2. The card has a lithium battery that allows the clock to work during
3/5 years (see drawing D50).
9.3.4
MENU 3. PROGRAMME ADJUSTMENT (TIMETABLE SCHEDULE OF THE THERMO STOVE OR
INSERT)
IMPORTANT NOTE: Before starting the set up of the thermo-stove or insert, please check that the time and
date shown are correct. Otherwise, the selected programming would be set up depending on the time and
date set by default and this could not satisfy your needs.
The following table briefly describes the programming menu structure in the thermo-stove or insert where are detailed all the different
options:.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
Sub-menu
Winter / Summer
01- Day
02- Hour
03- Minute
04- Day
05- Month
06- Year
** See point 10.3.3.
01 - Italian
02 - French
03 - English
04 - German
05 - Portuguese
06 - Spanish
ON/OFF
ON/OFF
Set
Internal probe
Cont. probe Remote
Provides information on the status of the thermo-stove
or insert.
44
Menu 01
WINTER
SEASON
MENU
D49
06
Menu 02
MONTH
CLOCK
MENU
D50
HYDRO SERIES RADIOFREQUENCY

Advertisement

Table of Contents
loading

Table of Contents