Bronpi hydro series Installation, Operating And Servicing Instruction page 50

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 28
will be automatically turned off and it will wait until the ambient temperature falls to the
set temperature minus a differential (2ºC). After that, the thermo-stove or insert restarts
automatically.
9.4.6
BURNER CLEANING
While the thermo-stove or insert is working normally, automatic cleaning of the burner
takes place in several minutes intervals. This process consists of cleaning the
remaining pellet in the burner in order to guarantee proper working of the thermo-
stove or insert (see drawing D82) and it takes several seconds.
9.4.7
TURNING OFF THE THERMO STOVE OR INSERT
In order to ignite the thermo-stove or insert, press button no.3 during a few seconds.
Once it has been turned off, it will start the final cleaning stage, in which the pellet supply stops and the smoke extractor will work at the
maximum speed. This stage does not finish until the thermo-stove or insert has
reached the appropriate cooling temperature (see drawing D83).
9.4.8
THERMO STOVE OR INSERT TURNED OFF
When the thermo-stove or insert is turned off, the display shows the following
information (see drawing D84):
9.4.9
RE-IGNITION OF THE STOVE OR INSERT
Once the thermo-stove or insert is turned off it is not possible to restart it until a safety
lock out period is passed and the thermo-stove or insert is cold enough. If you try to
start-up the thermo-stove, the display will show the following information (see drawing
D85):
10 ALARMS
In case of an anomaly during operation, the electronics of the thermo-stove or
insert intervene and highlight the irregularities that have taken place in the standard
operation of the thermo-stove or insert, depending on the type of fault.
Every alarm situation puts the thermo-stove or insert to be an automatic "lock out"
state. By pressing button 3 we can unlock it. Once the thermo-stove or insert has
reached the appropriate cooling temperature, the user can restart it up.
10.1
POWER SUPPLY FAILURE (BLACK OUT)
In the event that power supply is cut for less than 30 seconds, the thermo-stove will
restart and continue with its normal working state.
In the event that power supply is cut for greater than 30 seconds, when power is
restored, the thermo-stove, as a safety measure, goes straight to the Final Cleaning
stage until the thermo-stove or insert temperature reaches the appropriate cooling temperature. Once the final cleaning has finished, the
thermo-stove or insert will turn off until the user manually ignites it again (see drawing
D86).
10.2
SMOKE TEMPERATURE PROBE ALARM
This alarm goes off when the probe in charge of detecting the exhaust smoke
temperature is disconnected or it fails. During the alarm status, the thermo-stove or
insert will move to the turn-off stage (see drawing D87).
10.3
SMOKE TEMPERATURE EXCESS ALARM
It goes off when the probe detects a smoke temperature higher than 270°C. The
remote control will show the following message (see drawing D88):
During the alarm state, the thermo-stove or insert will be in the turn-off stage.
10.4
DAMAGED SMOKE EXTRACTION FAN ALARM
This alarm goes off when the smoke extraction fan breaks down. If this happens, the thermo-stove or insert
stops and the remote control will show the following alarm (see drawing D89). Right after, the turn-off stage will
be immediately activated.To deactivate the alarm press button 3 and the thermo-stove or insert will return to the
normal state after carrying out the final cleaning.
10.5
IGNITION FAILURE ALARM
In case of ignition failure (after 20 minutes at least) the control will show up an alarm as follows (see drawing
D90).
To deactivate the alarm press button 3 and the thermo-stove or insert will come to the normal state after doing the
final cleaning.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
16:40
22º C
CLEANING
BURNER
MENU
21:10
23º C
OFF
MENU
12:42
22º C
CLEANING
FINAL
MENU
ALARM 3
TEMP. SMOKE
MENU
49
21:10
65ºC
23º C
65ºC
CLEANING
FINAL
MENU
D82
65ºC
WAITING
COOLING
MENU
D84
ALARM 2
65ºC
SMOKE PROBE
MENU
D86
ALARM 4
FAILURE
VENT-SMOKE
MENU
D88
ALARM 5
FAILURE
IGNITION
MENU
HYDRO SERIES RADIOFREQUENCY
D83
D85
D87
D89
D90

Advertisement

Table of Contents
loading

Table of Contents