Standard Motion
Overview
In START mode, the motion buttons activate the associated motion relays that command the
hoisting system movements.
Triggering Procedure
Required conditions: The Wireless Remote Control System must be in START mode
(see page
125).
Triggering procedure:
Step
Action
1
Check that the Wireless Remote Control System is in START mode.
2
Press a motion button 1, 1H, 2, 2H, 3, 3H, 4, 4H, 5, 5+7, 6, 6+7
Result: The associated relays are switched ON as long as the motion button is pressed.
The Remote Device has no specific result.
Release
Release procedure:
Step
Action
1
Release the motion button.
Result: The associated relays are switched OFF.
Restrictions for Motion/Auxiliary Use
Type
Number of
simultaneous
motions
Interlocking
Buttons 5 and 6
EIO0000001505 12/2014
Description
Only up to 6 motion/auxiliary relays can be activated at the same time (excluding the
UOC relays).
If more than 6 motion/auxiliary relays are requested (excluding the UOC relays), then the
last motion relay request is not take into account.
If 2 buttons dedicated to same motion axis are pressed in opposite sense (interlocking),
then the motion is stopped in these both directions.
The button 7 must be released to activate the button 5 or 6.
Using The Wireless Remote Control System
(see page
24).
131