Detected Applicative Alarm

Overview
The ZARB18• Base Station implements 6 inputs: IN1...IN6.
Different sensors can be connected to these inputs.
These inputs are dedicated for applicative alarms.
Description
The detected applicative alarms are only displayed on the ZART•D Remote Device.
Factory settings:
Input
IN1
IN2
IN3
IN4
IN5
IN6
You can configure the detected applicative alarm inputs with the eXLhoist Configuration Software
(see page
199).
General Wiring Rules
The I/O and power supply cables should be AWG 16 (cross-sectional conductor area = 1.3 mm
The I/O and power supply cable lengths should not exceed 20 m (65.6 ft).
For more details, refer to Wiring Best Practices
EIO0000001505 12/2014
Description
Overload pre-alarm
Overload alarm
Over wind pre-alarm
Over wind alarm
Over speed alarm
Generic alarm
(see page
Installation and Wiring
91).