Testing and
The effective UV radiation from the lamp used for curing models can change 
Calibrating the
over time. Too little UV curing can cause some of the printing material to 
UV Lamp
remain in a liquid state, on models, when printing has finished. Test the lamp 
and calibrate its effective UV radiation after every 300 hours of printing, or 
when you suspect that this is necessary, by running the UV Calibration 
Wizard.
The wizard compares the measured radiation to the recommended radiation 
level. When calibrating the lamp, the wizard attempts to adjust the radiation 
level, if necessary.
• If the reading is within the acceptable range, the wizard continues. 
• If further adjustment is necessary, the test is repeated. 
• If the UV radiation is too low to be properly adjusted, the wizard indicates 
Before testing and calibrating the UV lamp, make sure the glass lens is 
clean. For easy access, run the Head Cleaning Wizard, and use the 
special cleaning pad supplied.                                
To test and calibrate UV lamp radiation:
1.  Start the UV Calibration Wizard from the Options menu (see  on page 6-
2.  In the following screen, select UV Intensity Calibration to adjust the lamp's 
3.  Make sure that the build tray is clear (empty). Confirm this in the wizard 
DOC-34022 Rev. D
that the lamp's radiation for the printing mode is unacceptable.
31).
radiation level to the acceptable range. 
Figure 6-83    UV Test/Calibration selection
screen and click Next.
6 Operating and Maintaining the Objet30 3D Printer
6-63