Chapter 7
7) Remove the multifeeder unit [1].
- Screws [2] 4 pcs.
[1]
[2]
8) Remove the harness from the guide.
- connector [1] 1 pc.
9) Remove the multifeeder pickup solenoid [2].
- Screw [3] 1 pc.
[2]

7.5.11 Registration Roller

7.5.11.1 Removing the Registration Roller

1) Open the front cover.
2) Turn the developer pressure release lever clockwise, and then open the left
door.
3) Draw out the drum unit.
7-22
F-7-52
[3]
[1]
F-7-53
4) Remove the two metal plates [1], and remove the registration roller [2].
- Screws [3] 2 pcs.
[3] [1]

7.5.12 Registration Clutch

7.5.12.1 Removing the Registration Clutch

1) Remove the rear cover.
2) Disconnect the connector [1], and then remove the harness from the three
wire saddles [2].
3) Remove the resin ring [3], and then remove the registration clutch [4].
0020-4438

7.5.13 Separation Roller

7.5.13.1 Removing the Feed and Separation Rollers

1) Remove the cassette.
2) Open the lower-left cover.
[2]
[2]
[3]
[1]
F-7-54
[1]
[4]
[2]
F-7-55
0020-4440
[3]
0020-4441