Title
Item
Service's

Scan Setting

Choice
Printer
Setting

Adjust

CIS Position
Adjust
Reading
Adjust
Print
Position
14-2
Sub item
Initial setting
Define LGL Size
Legal
Define LTR Size
LTR
Define LTR-R Size
LTR-R
Shading Value-R
272
Shading Value-G
272
Shading Value-B
272
BitSwitch14
All off
BitSwitch15
All off
Fuser Temp.-Bypass
6
Fuser Temp.-Tray1
6
Fuser Temp.-Tray2
6
Fuser Temp.-Tray3
6
Fuser Temp.-Tray4
6
Film Speed-Bypass
15
Film Speed-Tray
15
Define U1 Paper Size
G-LTR
Define U2 Paper Size
Foolscap
Define U3 Paper Size
G-LGL
Print Test-Page
-
Print Test-Interval
-
B4-Large/Small
Small
EUR:Operator
call, Other
country/
region:Service
Waste Toner Full
call
Shading Position
22
Sheet Position
385
Book Main Regist
35
Book Sub Regist
115
Book Mian Zoom
16
Book Sub Zoom
16
Motor Phase2-1(CW)
474
Motor Phase2-1(CCW)
474
ADF Main Regist
35
ADF Sub Regist-DES
220
ADF Sub Regist-Copy
24
ADF Main Zoom
16
ADF Sub Zoom
16
ADF Motor Zoom
16
Top-Bypass
50
Top-Tray
50
Top-Duplex
50
Left-Bypass
100
Left-Tray1
100
Left-Tray2
100
Left-Tray3
100
Left-Tray4
100
Left-Duplex
100
Range of setting
Function
Legal, Foolscap, M-Officio,
A-Foolscap, Folio, G-Legal,
A-Officio, B-Officio,
ADF special paper, standardized size: LGL
Officio, E-Officio
misidentification-ready
ADF special paper, standardized size: LTR
LTR, G-LTR, A-LTR
misidentification-ready
LTR-R, Foolscap, Officio,
E-Officio, G-LTR-R, A-
ADF special paper, standardized size: LTR_R
LTR-R
misidentification-ready
0 to 511
shading target value (red)
0 to 511
shading target value (green)
0 to 511
shading target value (blue)
On, Off
Special mode setting
On, Off
Delivery setting
0 to 12, 1 unit = 5 deg C
Target fixing temperature adjustment (multi)
0 to 12, 1 unit = 5 deg C
Target fixing temperature adjustment (cassette 1)
0 to 12, 1 unit = 5 deg C
Target fixing temperature adjustment (cassette 2)
0 to 12, 1 unit = 5 deg C
Target fixing temperature adjustment (cassette 3)
0 to 12, 1 unit = 5 deg C
Target fixing temperature adjustment (cassette 4)
Fixing film speed adjustment (manual paper feed
0 to 30, 1 unit = 0.4%
tray)
0 to 30, 1 unit = 0.4%
Fixing film speed adjustment (cassette)
Paper size group U1 special, standard-size paper
A-LTR, G-LTR, 8K
entry
Foolscap, Officio, E-Officio,
B-Officio, A-Officio, M-
Paper size group U2 special, standard-size paper
Officio, 16K
entry
A-Foolscap, A-LTR-R, G-
LTR-R, G-LGL, Folio,
Paper size group U3 special, standard-size paper
16KR
entry
-
Not used.
-
Not used.
Large, Small
Counter function setting
Operator call, Service call
Waste toner full display setting
Distance from the standby position of CIS to the
6 to 48, one unit=0.1mm
shading start point.
300 to 450, one unit=0.1mm CIS scan position during ADF scanning.
0 to 70, one unit=0.1mm
Vertical scan start position adjustment
50 to 150, one unit=0.1mm
Horizontal scan start position adjustment
0 to 32, one unit=0.1%
Horizontal scan magnification correction
0 to 32, one unit=0.1%
Vertical scan magnification correction
0 to 999, one
unit=0.0001mm
Adjust motor speed (CW)
0 to 999, one
unit=0.0001mm
Adjust motor speed (CCW)
0 to 70, one unit=0.1mm
Adjust ADF horizontal scanning start position
170 to 270, one unit=0.1mm Adjust ADF vertical scan start position from DES
Adjust ADF vertical scan start position from DES
0 to 200, one unit=0.1mm
(Copy)
0 to 32, one unit=0.1%
Adjust ADF horizontal Magnification correction
0 to 32, one unit=0.1%
Adjust ADF vertical scan end position
0 to 32, one unit=0.1%
Adjust ADF motor magnification correction
Top registration adjustment (manual paper feed
0 to 100, one unit=0.1mm
tray)
0 to 100, one unit=0.1mm
Top registration adjustment (cassette)
0 to 100, one unit=0.1mm
Top registration adjustment (duplex unit)
Left-end registration adjustment (manual paper feed
0 to 200, one unit=0.1mm
tray)
0 to 200, one unit=0.1mm
Left-end registration adjustment (cassette 1)
0 to 200, one unit=0.1mm
Left-end registration adjustment (cassette 2)
0 to 200, one unit=0.1mm
Left-end registration adjustment (cassette 3)
0 to 200, one unit=0.1mm
Left-end registration adjustment (cassette 4)
0 to 200, one unit=0.1mm
Left-end registration adjustment (duplex unit)