(f) Connect magnetic field coil wire to terminal C.
(h) Torque:
(i) Clamp starter with jaw vice.
(j) As shown in the diagram, connect battery with ampere
meter.
(k) Read current value displayed on ampere meter.
(l) Current value specification: 90 A or lower at 11.5 V.
2. Starter relay
Conditions
Normal state
Supply battery voltage
to No. 1 and No. 2
terminals
80
Starting and charging - Starting system
Terminal connected
by three-use meter
Specified
conditions
Conduction
Conduction
Ampere
Terminal 30
Terminal 50
meter