CHAPTER 7 TROUBLESHOOTING
A shift of the ADF upward by 1 mm will increase the registration along the
left bottom of the paper by about 0.5 mm.
Memo
3) Place A4 (LTR) paper in the cassette or the manual feed tray.
4) Open the ADF, and place an A5 (STMTR) original on the copyboard glass.
5) Close the ADF, and make a copy in Direct.
6) Check the copy image, and check to make sure that the area outside the image is free of
fogging.
7) If fogging is found, the position of the white sheet may be wrong; check its positioning.
If no fault is found, try skew removal once again.

1.3.3.2 Left/Right Registration Adjustment

Using the ADF, make a copy of the sheet in Direct, and check to make sure the left/right
registration is 10 ± 1 mm. (See 1.2.2 of Chapter 7.)
(feeding direction)
1) Pick the tab [1], and detach the white plate [2].
7-10
COPYRIGHT © 2001 CANON INC.
10±1mm
F07-103-03
[2]
[1]
F07-103-04
2000 2000 2000 2000
Copy of the test sheet
CANON SmartBase PC1200s/iR1200s REV. 0 DEC. 2001