Removing The Dc Controller Pcb/Power Supply Pcb - Canon SmartBase PC1200s Service Manual

Hide thumbs Also See for SmartBase PC1200s:
Table of Contents

Advertisement

2.2.4 Removing the DC Controller PCB/Power Supply PCB

1) Remove the rear cover. (See 2.1.1.1)
2) Remove the delivery cover. (See 2.1.1.4)
3) Disconnect the 4 connectors [1] used to
connect the image processor PCB and
the power supply unit.
4) Disconnect the connector [2] used to
connect the NCU PCB and the power
supply unit.
5) Disconnect the connector [3], and free
the harness [4] from the harness guide
[5].
6) Disconnect the 3 connectors [6].
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON SmartBase PC1200s/iR1200s REV. 0 DEC. 2001
CHAPTER 5 MECHANICAL SYSTEM
[1]
[3]
[4]
[5]
F05-202-09
[6]
F05-202-10
[4]
[2]
[6]
[6]
5-21