2.6 Pickup/Feeding System

2.6.1 Removing the Cassette Pickup Roller

1) Remove the ADF (copyboard cover).
(ADF; See 2.8.1.1)
2) Remove the cassette.
3) Place the machine so that its pickup side
is at the bottom.
4) Remove the 8 screws [1], and detach the
bottom plate [2].
COPYRIGHT © 2001 CANON INC.
2000 2000 2000 2000
CANON SmartBase PC1200s/iR1200s REV. 0 DEC. 2001
CHAPTER 5 MECHANICAL SYSTEM
F05-206-01
[2]
F05-206-02
[1]
[1]
5-35