Original Exposure System

Right angle adjustment

Place a test chart on the ADF and make a copy. Then measure A and B dimensions of the leading edge of paper. If the skew
amount is not within the standard, perform this adjustment.
• Standard value: A - B = 0 +/- 1.5 mm
1. Loosen the 4 Right Hinge Fixation Screws and make the adjustment by moving the hinge installation position back
and forth.
2. Place a test chart on the ADF again and make a copy again.
3. Repeat the steps 1 to 2 until the skew amount falls within the specified value.
4. When the skew amount is within the range, tighten the Fixation Screws you loosened.
A
Feed direction
Copy of the test chart
B
[1]
313
[2]
[2]
4x
5. Adjustment
[1]

Advertisement