3.21.7 AGING Test (5: AGING TEST)
Not used.

3.21.8 FACULTY (function) Test (6: FACULTY TEST)

A press on '6' on the keypad from the TEST MODE menu selects the FACULTY test. A
press on the keypad (1 through 7, 9, #) during the test will bring up the following menu:
Keypad
Item
1
G3 Signal Transmission Test
2
not used
3
Sensor Test
4
ADF Test
5
not used
6
Speaker Test
7
Control Panel Test
9
Live Connection Reception Test
#
ESS Test
G3 Signal Transmission Test (6-1: G3 4800 bps Tx)
A press on '1' on the keypad on the FACULTY TEST menu selects the G3 transmission
test. In this test, a G3 signal is transmitted using the telephone line terminal and the speaker
at 4800 bps.
Sensor Test (6-3: SENSOR)
This mode is used to check the state of a specific sensor of the machine on the LCD. A
press on '3' on the keypad from the FACULTY TEST menu selects the sensor test. The LCD
indication changes as the sensor goes ON and OFF.
2-80
COPYRIGHT © 2001 CANON INC.
Description
Transmits a G3 signal at 4800 bps to the telephone
line and the speaker.
Executes an operation test on a specific sensor.
Executes an operation test on the ADF.
Executes an operation test on the speaker.
Executes an operation test on the LCD/LED/control
panel keys.
Executes an operation test on the signal sensor on
the NCU board and the frequency counter.
Executes an operation test on the ESS function.
2000 2000 2000 2000