1.3.3 Adjusting the Mechanical Systems

1.3.3.1 Removing the Skew

Make a copy of the test sheet using the ADF in Direct, and make sure that the skew is as
indicated (T07-103-01). (See 1.2.2 of Chapter 7.)
(feeding direction)
b-a
1) Open the ADF.
2) Loosen the 3 screws [1], and move the left hinge up and down so that the skew will be
as indicated by referring to the index graduated at 1-mm intervals.
COPYRIGHT © 2001 CANON INC.
a
b
F07-103-01
Dimension (using A4)
0 ± 1.3 mm
T07-103-01
[1]
F07-103-02
2000 2000 2000 2000
CHAPTER 7 TROUBLESHOOTING
Copy of the test sheet
Dimension (using LTR)
0 ± 1.3 mm
CANON SmartBase PC1200s/iR1200s REV. 0 DEC. 2001