Fuel Gauge Installation; Oil Meter Inspection; Oil Meter Operation Inspection - KYMCO SUPER8 50 2T Service Manual

Hide thumbs Also See for SUPER8 50 2T:
Table of Contents

Advertisement

16
. INSTRUMENT/SWITCHES/LIGHTS
INSTALLATION
The installation sequence is the reverse of
removal.
• Install the fuel unit at the connect
position.
OIL METER
INSPECTION
Remove the met-in box. ( 12-4)
Remove the frame body cover. ( 12-4)
Disconnect the oil meter wire connectors
and remove the oil meter. Keep the oil
meter float at the lower position.
Measure the resistances between the wire
terminals as
and
figure.
Wire Terminals
Green/Red(+)~Black(-)
Green(-)~Black(+)
Before removing the oil meter, be sure
to drain the motor oil and do not allow
sparks or flames near the working area.

Oil Meter Operation Inspection

Connect the oil meter wire connectors and
turn the ignition switch ON.
Measure the resistance between the wire
terminals with the float at upper position.
Green/Red(+)~Black(-)
Before performing the following test,
operate the turn signals to determine
that the battery circuit is normal.
16-3
shown in the left
Resistance
46Ω
About 300Ω
Fuel Unit
Wire Connector
Oil Meter
G/R
Float
Light OFF
Light ON
SUPER8 50 2T
B
G
B
4.5±1.0mm
Light OFF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents