Resistor Inspection; Regulator/Rectifier Inspection - KYMCO SUPER8 50 2T Service Manual

Hide thumbs Also See for SUPER8 50 2T:
Table of Contents

Advertisement

15
. ELECTRICAL EQUIPMENT

RESISTOR INSPECTION

Remove the frame front cover. ( 12-3)
Measure the resistance between the resistor
with ground.
Resistances:
Resistor: 9.9~12.0Ω
Faulty resistor is the cause of faulty
operation of the auto bystarter.

REGULATOR/RECTIFIER INSPECTION

Remove the front cover. ( 12-3)
Disconnect the regulator/rectifier wire coupler
and remove the bolt to remove the
regulator/rectifier.
Measure the resistances between the
terminals.
Replace the regulator/rectifier if the readings
are not within the specifications in the table
below.
• Due to the semiconductor in circuit, it
is necessary to use a specified tester
for accurate testing. Use of an
improper tester in an improper range
may give false readings.
• Use a Sanwa Electric Tester (07208-
0020000) or Kowa Electric Tester
(TH-5H). The proper range for
testing is listed below.
Model
Brand
SP-10D
Sanwa
TH-5H
Kowa
Regulator/Rectifier
Range
KΩ
100Ω
Peach Red
SUPER8 50 2T
Resister
Coupler
Black
Yellow Green