15
. ELECTRICAL EQUIPMENT

CDI UNIT INSPECTION

Remove the front cover.
Disconnect the CDI coupler and remove the
CDI unit.

CDI CIRCUIT INSPECTION

Measure the resistance between the
terminals.
Replace the CDI unit if the readings are not
within the specifications in the table below.
• Due to the semiconductor in circuit, it is
necessary to use a specified tester for
accurate testing. Use of an improper
tester in an improper range may give
false readings.
• Use a Sanwa Electric Tester or Kowa
Electric Tester (TH-5H).
• In this table, "Needle swings then
returns" indicates that there is a charging
current applied to a condenser. The needle
will then remain at "∞" unless the
condenser is discharged.
Use the x KΩ range for the Sanwa Tester.
Use the x 100Ω range for the Kowa Tester.
Probe⊕
Black
(-)Prob
Black
Blue/
15~20KΩ
Yellow
Green
15~20MΩ 600~900Ω
Black/
Yellow
Unit:
Blue/
Black/
Green
Yellow
Yellow
4~7MΩ 4~7MΩ 2~3MΩ
600~900Ω
1000~1500KΩ
4~7MΩ
CDI Unit
Green
Black/ Yellow Black/ Red
Violet/ Black
Blue/ Yellow
SUPER8 50 2T
Black / Blue
Violet/Red
15-10