JUMO LOGOSCREEN Operating Manual page 107

Paperless recorder with compactflash card as storage medium
Hide thumbs Also See for LOGOSCREEN:
Table of Contents

Advertisement

Serial
interface
Device list
The following parameters must be selected.
Connected to
Transmission rate
Control signal
Communication
protocol
Device address
When all settings have been made, the device is entered in the device list.
COM1, COM2
9600, 19200, 38400
RS232
RS232 setup interface
(TTL)
RS422-RTS
RS422-DTR
RS485-RTS
RS485-DTR
Modbus TCP/IP,
Modbus protocol
1 — 255
5 Setup software
The PC interface to
which the paperless
recorder is connected.
The transmission rate
must match the one that
has been set in the
device.
If the RS232 interface
on the device is used.
If the setup interface on
the device is used.
If the RS422/485
interface on the device
is used.
Set the
Modbus protocol
here.
Device address for the
Modbus protocol.
If "RS232 setup
interface" is used as a
control signal, the
device address will be
ignored. It need not
match the address in
the device.
107