Fault
Item
Code No.
Error in writing the
44
amount of CO
adjustment on EEPROM
Vehicle system power
46
supply (Monitor voltage)
ECU internal malfunction
(memory check error)
50
Grip warmer switch
80
Grip warmer
81
Thumb warmer switch
82
Thumb warmer
83
T.O.R.S.
84
Oil pressure switch
85
Start unable warning
Communication error with the meter
Fault
Item
Code No.
ECU internal malfunction
Er-1
(output signal error)
ECU internal malfunction
Er-2
(output signal error)
ECU internal malfunction
Er-3
(output signal error)
ECU internal malfunction
Er-4
(input signal error)
FUEL INJECTION SYSTEM
Symptom
An error is detected while
reading or writing on EEPROM
(CO adjustment value).
Power supply to the FI system is
not normal.
Faulty ECU memory. When this
malfunction is detected, the
code number might not appear
on the meter.
Grip warmer switch-short circuit
detected.
Grip warmer-open or short
circuit detected.
Thumb warmer switch-short
circuit detected.
Thumb warmer-short circuit
detected.
Detecting conditions for T.O.R.S.
are satisfied.
Oil pressure switch-open circuit
detected.
Relay is not turned ON even if
the crank signal is input while
the start switch is turned ON.
When the start switch is turned
ON while an error is detected
with the fault code of No.11, 12,
30 or 50.
Symptom
No signals are received from the
ECU.
No signals are received from the
ECU within the specified dura-
tion.
Data from the ECU cannot be
received correctly.
Non-registered data has been
received from the meter.
62
Fail-safe action
Grip warmer output is OFF.
Engine trouble warning light
flashes when the start switch is
turned ON.
Fail-safe action
FI
Able/unable
Able/unable
to start
to drive
Able
Able
Able
Able
Unable
Unable
Able
Able
Able
Able
Able
Able
Able
Able
Able
Unable
Able
Able
Unable
Unable
Able/unable
Able/unable
to start
to drive
Unable
Unable
Unable
Unable
Unable
Unable
Unable
Unable