Application Of Silicon Grease To A Power Transistor And A Diode Bridge - Daikin CTXU25G2V1B Service Manual

Inverter multi system with humidifying
Hide thumbs Also See for CTXU25G2V1B:
Table of Contents

Advertisement

Others
1.3
Application of Silicon Grease to a Power Transistor and
a Diode Bridge
Applicable
Models
Details
<Example>
257
All outdoor units using inverter type compressor for room air conditioner.
When the printed circuit board of an outdoor unit is replaced, it is required that silicon grease
(*1) is certainly applied to the heat radiation part (the contact point to the heat radiation fin) of
the power transistor and diode bridge.
*1: Parts number of the silicon grease – 1172698 (Drawing number 3FB03758-1)
The silicon grease is an essential article for encouraging the heat radiation of the power
transistor and the diode bridge. Applying the paste should be implemented in accordance with
the following instruction.
Remark: There is the possibility of failure with smoke in case of bad heat radiation.
To completely wipe off the old silicon grease on a heat radiation fin.
To evenly apply the silicon grease to the whole.
Do not have any foreign object such as solder or paper waste between the power transistor,
the diode bridge and the heat radiation fin.
To firmly tighten the screws of the power transistor and the diode bridge, and to surely
contact to the heat radiation fin without any gap.
Take out a PCB
OK : Evenly applied
silicon grease.
Power transistor
(TRM, TPM, IGBT, IPM, SPM, etc.)
Diode bridge
(Diode bridge, Rectifier stack, etc.)
Not applied.
NG : Not evenly
NG : Foreign object.
applied
SiBE12-908
Paper wastage
(R9056)
Others

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ctxu35g2v1b2mxu40gv1bCtxu42g2v1b2mxu50gv1bCtxu50g2v1b