SiBE12-908
1.5

Removal of Electrical Box

Procedure
Step
The figure shows the
1
connections of wire
harnesses.
Remove the screw of
2
the electric wire
retaining plate to
remove the plate.
Remove the screws of
3
the terminal board and
disconnect the
connecting wires.
Disconnect the
4
connector of the fan
motor [S1].
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
[S1]
Points
Preparation
Remove the front grille
according to the "Removal
of Front Grille".
(R10305)
(R10306)
Terminal
board
(R10307)
(R10308)
Indoor Unit