Sign In
Upload
Manuals
Brands
Daikin Manuals
Air Conditioner
G-Series
Daikin G-Series Manuals
Manuals and User Guides for Daikin G-Series. We have
2
Daikin G-Series manuals available for free PDF download: Service Manual
Daikin G-Series Service Manual (319 pages)
Inverter Pair Wall Mounted Type
Brand:
Daikin
| Category:
Inverter
| Size: 15.22 MB
Table of Contents
Table of Contents
3
Introduction
7
Safety Cautions
7
Used Icons
11
Part 1 List of Functions
12
Functions
13
Cooling Only
13
Heat Pump
14
Part 2 Specifications
16
Specifications
17
Cooling Only
17
Heat Pump
20
Part 3 Printed Circuit Board Connector Wiring Diagram
28
Printed Circuit Board Connector Wiring Diagram
29
Indoor Unit
29
Outdoor Unit
32
Part 4 Function and Control
40
Main Functions
41
Frequency Principle
41
Airflow Direction Control
43
Fan Speed Control for Indoor Units
44
Program Dry Operation
45
Automatic Operation
46
Thermostat Control
47
NIGHT SET Mode
48
ECONO Operation
49
2-Area INTELLIGENT EYE Operation
50
INTELLIGENT EYE Operation
52
Inverter POWERFUL Operation
53
Other Functions
54
Function of Thermistor
55
Control Specification
56
Mode Hierarchy
56
Frequency Control
57
Controls at Mode Changing / Start-Up
59
Discharge Pipe Temperature Control
61
Input Current Control
62
Freeze-Up Protection Control
64
Heating Peak-Cut Control
64
Outdoor Fan Control
65
Liquid Compression Protection Function
65
Defrost Control
66
Electronic Expansion Valve Control
67
Malfunctions
70
Standby Electricity Saving
71
Part 5 Operation Manual
72
System Configuration
73
Ftxs20/25/35/42/50G2V1B
74
Remote Controller
74
AUTO · DRY · COOL · HEAT · FAN Operation
75
Adjusting the Airflow Direction
77
COMFORT AIRFLOW and INTELLIGENT EYE Operation
79
POWERFUL Operation
82
OUTDOOR UNIT QUIET Operation
83
ECONO Operation
84
TIMER Operation
85
WEEKLY TIMER Operation
87
Copy Mode
90
Atxs20/25/35/42/50G2V1B
92
Remote Controller
92
AUTO · DRY · COOL · HEAT · FAN Operation
93
Adjusting the Airflow Direction
95
COMFORT AIRFLOW Operation
97
INTELLIGENT EYE Operation
98
POWERFUL Operation
100
OUTDOOR UNIT QUIET Operation
101
ECONO Operation
102
TIMER Operation
103
Part 6 Service Diagnosis
105
Caution for Diagnosis
106
Troubleshooting with LED
106
Problem Symptoms and Measures
107
Service Check Function
108
ARC452 Series
108
ARC433 Series
111
Troubleshooting
114
Error Codes and Description
114
Indoor Unit PCB Abnormality
115
Freeze-Up Protection Control or Heating Peak-Cut Control
116
Fan Motor (DC Motor) or Related Abnormality
118
Thermistor or Related Abnormality (Indoor Unit)
120
Signal Transmission Error (between Indoor Unit and Outdoor Unit)
121
Unspecified Voltage (between Indoor Unit and Outdoor Unit)
122
Outdoor Unit PCB Abnormality
123
OL Activation (Compressor Overload)
125
Compressor Lock
126
DC Fan Lock
127
Input Overcurrent Detection
128
Four Way Valve Abnormality
129
Discharge Pipe Temperature Control
131
High Pressure Control in Cooling
133
Compressor System Sensor Abnormality
135
Position Sensor Abnormality
137
DC Voltage / Current Sensor Abnormality (20/25/35/42 Class)
140
CT or Related Abnormality (50 Class)
141
Thermistor or Related Abnormality (Outdoor Unit)
143
Electrical Box Temperature Rise
145
Radiation Fin Temperature Rise
147
Output Overcurrent Detection
149
Refrigerant Shortage
151
Low-Voltage Detection or Over-Voltage Detection
154
Signal Transmission Error on Outdoor Unit PCB (50 Class Only)
156
Check
157
How to Check
157
Thermistor Resistance Check
159
Installation Condition Check
160
Discharge Pressure Check
160
Main Circuit Short Check
166
Part 7 Removal Procedure
167
Indoor Unit
168
Removal of Air Filter
168
Removal of Front Panel
170
Removal of Front Grille
172
Removal of Horizontal Blades / Vertical Blades
175
Removal of Electrical Box
178
Removal of PCB
181
Removal of Indoor Heat Exchanger
186
Removal of Swing Motors
189
Removal of Fan Motor
193
Outdoor Unit - RK(X)S20-35G2V1B, ARXS20-35G2V1B
196
Removal of Outer Panels / Fan Motor
196
Removal of Electrical Box
205
Removal of Thermistors
209
Removal of PCB
211
Removal of Reactor / Partition Plate
214
Removal of Sound Blanket
216
Removal of Four Way Valve
217
Removal of Compressor
220
Outdoor Unit - RK(X)S20-35G2V1B9, ARXS20-35G3V1B
222
Removal of Outer Panels / Fan Motor
222
Removal of Electrical Box
231
Removal of PCB
234
Removal of Reactor / Partition Plate
242
Removal of Sound Blanket
244
Removal of Four Way Valve
246
Removal of Compressor
249
Outdoor Unit - RK(X)S42G2V1B, ARXS42G2V1B
251
Removal of Outer Panels
251
Removal of Electrical Box
253
Removal of PCB
258
Removal of Sound Blanket
263
Removal of Outdoor Fan / Fan Motor
265
Removal of Thermistors
268
Removal of Four Way Valve / Electronic Expansion Valve
269
Removal of Compressor
272
Outdoor Unit - RK(X)S50G2V1B, ARXS50G2V1B
275
Removal of Outer Panels
275
Removal of Outdoor Fan / Fan Motor
279
Removal of Electrical Box
283
Removal of PCB
288
Removal of Sound Blanket / Thermistors
291
Removal of Four Way Valve
293
Removal of Electronic Expansion Valve
294
Removal of Compressor
295
Part 8 Trial Operation and Field Settings
298
Pump down Operation
299
Forced Cooling Operation Mode
300
Trial Operation
302
Field Settings
304
Model Type Setting
304
When 2 Units Are Installed in 1 Room
304
Standby Electricity Saving
305
Facility Setting Jumper and Switch (Cooling at Low Outdoor Temperature)
306
Jumper and Switch Settings
307
Application of Silicon Grease to a Power Transistor and a Diode Bridge
308
Part 9 Appendix
309
Piping Diagrams
310
Indoor Unit
310
Outdoor Unit
311
Wiring Diagrams
315
Indoor Unit
315
Outdoor Unit
315
Advertisement
Daikin G-Series Service Manual (289 pages)
Inverter Multi for 2 Rooms
Brand:
Daikin
| Category:
Air Conditioner
| Size: 14.04 MB
Table of Contents
Table of Contents
3
Introduction
6
Safety Cautions
6
Used Icons
10
Part 1 List of Functions
11
List of Functions
12
Cooling Only Models
12
Heat Pump Models
17
Part 2 Specifications
24
Specifications
25
Indoor Units - Cooling Only
25
Duct Connected Type
27
Floor Standing Type
29
Ceiling Mounted Cassette Type
30
Outdoor Units - Cooling Only
31
Indoor Units - Heat Pump
33
Outdoor Units - Heat Pump
43
Part 3 Printed Circuit Board Connector Wiring Diagram
45
Printed Circuit Board Connector Wiring Diagram
46
Wall Mounted Type
46
Duct Connected Type
53
Floor / Ceiling Suspended Dual Type
55
Floor Standing Type
58
Ceiling Mounted Cassette Type (600×600)
60
Outdoor Units
63
Part 4 Function and Control
65
Main Functions
66
Temperature Control
66
Frequency Principle
66
Power-Airflow Flaps, Wide-Angle Louvers, Auto-Swing, COMFORT AIRFLOW Mode and 3-D Airflow
68
Operation Starting Control
70
Fan Speed Control for Indoor Units
71
Program Dry Function
73
Automatic Operation
74
Thermostat Control
75
Night Set Mode
76
ECONO Mode
77
Area Intelligent Eye (Ftxs)
78
Intelligent Eye (Atxs, Ftxg, Atxg, Ctxg)
80
HOME LEAVE Operation
82
Inverter POWERFUL Operation
83
Other Functions
84
Weekly Timer Operation
85
Function of Thermistor
86
Heat Pump Model
86
Cooling Only Model
88
Control Specification
89
Mode Hierarchy
89
Frequency Control
90
Controls at Mode Changing / Start-Up
93
Compressor Protection Function
94
Discharge Pipe Temperature Control
95
Input Current Control
95
Freeze-Up Protection Control
96
Heating Peak-Cut Control
96
Fan Control
97
Liquid Compression Protection Function 2
97
Defrost Control
98
Electronic Expansion Valve Control
99
Malfunctions
103
Additional Function
104
Part 5 Operation Manual
105
System Configuration
106
Operation Instructions
106
Instruction
107
ATXS, ATX, FTXG, CTXG, ATXG, FDK(X)S, FLK(X)S Series
107
Remote Controller
108
Adjusting the Airflow Direction
115
Adjusting the Air Flow Direction
119
Comfort Airflow Operation
123
Powerful Operation
124
Outdoor Unit Quiet Operation
125
Econo Operation
126
Intelligent Eye Operation
130
Timer Operation
134
To Use on Timer Operation
135
Note for Multi System
136
FTXS, FVXS Series
138
Comfort Airflow and Intelligent Eye Operation
147
Quiet Operation
151
FFQ Series
162
Safety Considerations
164
Installation Site
165
Operation Range
165
Switch and Display on the Remote Controller
166
Operation Procedure
166
Trouble Shooting
172
Part 6 Service Diagnosis
173
Caution for Diagnosis
174
Problem Symptoms and Measures
176
Service Check Function
177
ARC433 Series
177
ARC452 Series
180
Troubleshooting
183
Error Codes and Description
183
Indoor Unit PCB Abnormality
184
Freeze-Up Protection Control or High Pressure Control
185
Fan Motor or Related Abnormality
187
Thermistor or Related Abnormality (Indoor Unit)
191
Front Panel Open / Close Fault
192
Freeze-Up Protection Control
193
OL Activation (Compressor Overload)
195
Compressor Lock
196
DC Fan Lock
197
Input Overcurrent Detection
198
Discharge Pipe Temperature Control
200
High Pressure Control in Cooling
201
Compressor Sensor System Abnormality
203
Position Sensor Abnormality
204
DC Voltage / DC Current Sensor Abnormality
206
Thermistor or Related Abnormality (Outdoor Unit)
207
Electrical Box Temperature Rise
209
Radiation Fin Temperature Rise
211
Output Overcurrent Detection
213
Refrigerant Shortage
215
Over-Voltage Detection / Low-Voltage Detection
217
Anti-Icing Function in Other Rooms / Unspecified Voltage (between Indoor and Outdoor Units)
218
Outdoor Unit PCB Abnormality or Signal Transmission Circuit Abnormality
219
Check
222
How to Check
222
Electronic Expansion Valve Check
223
Four Way Valve Performance Check
224
Thermistor Resistance Check
225
Installation Condition Check
226
Discharge Pressure Check
227
Power Supply Waveforms Check
227
Power Transistor Check
228
Hall IC Check
231
Part 7 Removal Procedure
235
Outdoor Unit
236
Removal of the Panels and Plates
236
Removal of the Electrical Box
238
Removal of the PCB
243
Removal of the Sound Blanket
248
Removal of the Outdoor Fan / Fan Motor
250
Removal of the Thermistors
253
Removal of the Compressor
255
Removal of the Four Way Valve / Electronic Expansion Valve
257
Part 8 Trial Operation and Field Settings
259
Pump down Operation
260
Forced Cooling Operation Mode
261
Trial Operation
262
Indoor Unit - ATX, ATXS, ATXG, F(C)TXG, FTXS, FDK(X)S, FLK(X)S, FVXS Series
262
Indoor Unit - FFQ Series
264
Field Settings
265
RA Indoor Unit - ATX, ATXS, ATXG, F(C)TXG, FTXS, FDK(X)S, FLK(X)S, FVXS Series
265
Jumper and Switch Settings
268
Indoor Unit - FFQ Series
269
Outdoor Unit
272
Maximum Power Input Limitation Setting
273
Application of Silicon Grease to a Power Transistor and a Diode Bridge
274
Part 9 Appendix
275
Piping Diagrams
276
Indoor Units
276
Outdoor Units
280
Heat Pump
281
Wiring Diagrams
282
Indoor Units
282
Outdoor Units
287
Advertisement
Related Products
Daikin GPGM5
Daikin GTKM50UV16V3
Daikin GTKL50UV16V
Daikin GTKL50UV16U
Daikin GTKY50UV16V3F
Daikin GTL28UV16W1
Daikin GTL50UV16V7
Daikin GTQ60UV16U5
Daikin GTQ50UV16U2
Daikin GTKC35UV16W3
Daikin Categories
Air Conditioner
Heat Pump
Remote Control
Chiller
Fan
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL