Installation Manual

1. Installation Manual

1.1

Indoor Units

Indoor Unit Installation Drawings
A
Mounting plate
Screws
(Field supply: M4 × 25L)
Front panel
50mm or more
from walls
(on both sides)
Air filters
(Left side)
B , C
Titanium apatite photocatalytic
air-purifying filter
B (short)
Filter frame
Tab
Air filters
INTELLIGENT EYE sensor
CAUTION
1) Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and malfunction.
2) Do not place large objects near the sensor. Also keep heating units or humidifiers outside the sensor's detection area.
3
55
How to attach the indoor unit.
Hook the claws of the bottom frame
to the mounting plate.
If the claws are difficult to hook,
remove the front grille.
How to remove the indoor unit.
Push up the marked area (at the
lower part of the front grille) to
release the claws. If it is difficult to
release, remove the front grille.
The mounting plate
should be installed on a
wall which can support the
weight of the indoor unit.
M4 × 16L
M4 × 16L
Air filters
In upward direction
(Right side)
C (long)
Air supply filter (gray)
•Hold the knob to pull up.
E
Wireless
remote
controller
Screws
(field supply: M3 × 20L)
Front grille
30mm or more
from ceiling
Humidifying
hose
INTELLIGENT
EYE sensor
D
Air supply filter (gray)
Filter frame
Tabs
(4 locations)
Air supply
filter
Filter frame
Holes
(4 locations)
Before screwing the remote
controller holder to the wall, make
sure that control signals are
properly received by indoor unit.
F
Remote
controller holder
SiBE12-908
Mounting
A
plate
Clip
Bottom frame
Mark (rear side)
If it is difficult to lay the humidifying
hose, cut it, lay it, and connect it using
the joint included with the outdoor unit.
Do not install the trap to
the humidifying hose as
much as possible.
Install the hose with
a downward slope.
Cut thermal insulation
pipe to an appropriate
length and wrap it with
tape, making sure that
no gap is left in the
insulation pipe's cut line.
Wrap the insulation
pipe with the finishing
tape from bottom to top.
Service lid
Opening service lid
Service lid is opening/closing type.
Opening method
1) Remove the service lid screws.
2) Pull out the service lid diagonally
down in the direction of the arrow.
3) Pull down.
Installation / Operation Manual