Removal Of Swing Motor - Daikin CTXU25G2V1B Service Manual

Inverter multi system with humidifying
Hide thumbs Also See for CTXU25G2V1B:
Table of Contents

Advertisement

SiBE12-908
1.9

Removal of Swing Motor

Procedure
Step
1. Removing the swing motor
for vertical blade
Release the 2 hooks at
1
the bottom.
Lift the indoor unit by a
wooden base.
2
Remove the screw
behind the drain hose,
and disconnect the
drain hose.
Remove the screw at
3
the rear, and the
screws on the left and
right side of swing
motors.
Removal Procedure
Warning
Be sure to turn off all power supplies at least 10 minutes before
disassembling work.
Procedure
Drain hose
Swing motors
(R10323)
(R10329)
(R10330)
Indoor Unit
Points
206