Outdoor Unit
2.8

Removal of Electrical Box

Procedure
Step
1. Disconnect the
connecting wires
Remove the 2
1
grounding screws.
Remove the 2 screws
to remove the wiring
fixture.
Then, remove the all
screws for the
connectors to
disconnect the power
supply cable and the
connecting wires.
2. Removal of the electrical
box
Release the outdoor air
1
thermistor from the
holder.
Lift up the guard net to
2
remove.
231
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Room A
4
4
P
Wiring fixture
Grounding screw
Outdoor air thermistor
Room B
Power
supply
(R9935)
(R9936)
Guard net
(R9937)
SiBE12-908
Points
When reassembling, fasten
the wires with screws on the
terminal board.
The terminal board is united
resin formation.
Removal Procedure