SiBE12-908
2. Trial operation mode:
Refer to the installation manual on page 66 for detail.
3. Pipe set mode:
You can set the humidifying hose length and then check the preset value.
Refer to the installation manual on page 65 for detail.
4. Pipe check mode:
You can check the preset value of the humidifying hose length.
Refer to the installation manual on page 65 for detail.
5. Drying mode:
Refer to the installation manual on page 66 for detail.
6. Humidifying airflow rate setting mode:
Humidifying airflow rate setting mode allows to fine-tune the speed of the humidifying fan
around ±10% relative to Automatic. Set high to increase the airflow rate, or set to low to
decrease.
7. Monitor brightness setting mode:
The brightness of the multi-colored indicator lamp can be adjusted H (high), L (low), or OFF.
Function and Control
You can select a mode for trial operation on the remote controller.
The operation continues for approx. 30 minutes.
Hose Dry operation is a forced drying operation for humidifying hose.
The operation continues for approx. 30 minutes.
Cooling, heating, or dry operation is not available during Hose Dry operation.
Main Functions
36