Removal Of Damper Motor - Daikin CTXU25G2V1B Service Manual

Inverter multi system with humidifying
Hide thumbs Also See for CTXU25G2V1B:
Table of Contents

Advertisement

SiBE12-908
2.3

Removal of Damper Motor

Procedure
Step
1. Removal of the damper
motor
1
Disconnect the
connector for the
damper motor.
Removal Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Humidifying thermistor
Disconnect the connector
for the humidifying rotor
motor. (Refer to page 219.)
Harness ASSY
Damper
motor
(R10348)
(R0232)
Outdoor Unit
Points
220

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ctxu35g2v1b2mxu40gv1bCtxu42g2v1b2mxu50gv1bCtxu50g2v1b

Table of Contents