SiBE12-908
2.3
Removal of Damper Motor
Procedure
Step
1. Removal of the damper
motor
1
Disconnect the
connector for the
damper motor.
Removal Procedure
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Humidifying thermistor
Disconnect the connector
for the humidifying rotor
motor. (Refer to page 219.)
Harness ASSY
Damper
motor
(R10348)
(R0232)
Outdoor Unit
Points
220