2.6

Removal of Hygroscopic Fan Rotor / Hygroscopic Fan Motor

Procedure
Step
1. Removal of the
hygroscopic fan rotor
ASSY
Disconnect the
1
connector for fan motor
and remove the bell
mouth on adsorption
side.
2
Unscrew the fan fixing
nut (M6) of the
hygroscopic fan rotor
ASSY (sirocco fan rotor
ASSY) and remove.
2. Removal of the
hygroscopic fan motor
Remove the 3 screws
1
of the motor cover.
2
Remove the
hygroscopic fan motor.
227
Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Fan fixing
nut
Hygroscopic
fan motor
Preparation
Remove the humidifying
rotor according to "Removal
of Humidifying Rotor".
(R9928)
When reassembling, align
the
motor shaft.
Spanner size: 10mm
Hygroscopic
fan rotor
ASSY
Lift the motor cover first and
pull out.
Motor cover
SiBE12-908
Points
mark and D cut of the
Removal Procedure