Daikin CTXU25G2V1B Service Manual page 220

Inverter multi system with humidifying
Hide thumbs Also See for CTXU25G2V1B:
Table of Contents

Advertisement

Indoor Unit
Step
2. Removing the swing motor
for horizontal blade
1
Remove the screw to
remove the swing
motors for horizontal
blades.
Disconnect the
2
harnesses from the
motors.
209
Procedure
Screw
Connector for
upper blade (white)
When reassembling, do not
confuse the installing order
of the 2 motors and the
colors of the connectors.
Connector for
lower blade (red)
If you set the connectors or
motors opposite, the
horizontal blades do not
move smoothly or the noise
may be heard.
Set the motor for the upper
blade first.
(connector: white)
Then, set the motor for the
(R8131)
lower blade.
(connector: red)
Fix the both motors with a
screw.
(R8132)
(R10335)
SiBE12-908
Points
Caution
Removal Procedure

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ctxu35g2v1b2mxu40gv1bCtxu42g2v1b2mxu50gv1bCtxu50g2v1b

Table of Contents