Removal Of Horizontal Blades And Vertical Blades - Daikin CTXU25G2V1B Service Manual

Inverter multi system with humidifying
Hide thumbs Also See for CTXU25G2V1B:
Table of Contents

Advertisement

SiBE12-908
1.4

Removal of Horizontal Blades and Vertical Blades

Procedure
Step
1. Removing the horizontal
blade (large)
Open the horizontal
1
blade (large).
Unfasten the center
2
fixing shaft while
bending the horizontal
blade slightly.
3
Unfasten the left fixing
shaft of the horizontal
blade (large).
4
Unfasten the right fixing
shaft of the horizontal
blade (large).
Removal Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Horizontal blade (large)
Horizontal blade (small)
Cautions on Mounting
Mount the large horizontal
blade to the upper side and
the small horizontal blade to
the lower side.
Do not put them in the
wrong place.
(R10294)
There is a key alignment
mark at the right side. Insert
the key first while turning.
(R7922)
After key alignment at the
right side, mount the flap
first to the center fixing shaft
and then to the left fixing
shaft.
(R7923)
(R10295)
Indoor Unit
Points
190