Inverter
RZQ71~125B7V3B
User Manuals: Daikin RZQ71~125B7V3B Sky-Air Inverter
Manuals and User Guides for Daikin RZQ71~125B7V3B Sky-Air Inverter. We have
1
Daikin RZQ71~125B7V3B Sky-Air Inverter manual available for free PDF download: Service Manual
Daikin RZQ71~125B7V3B Service Manual (484 pages)
Sky-Air Inverter R-410A B series
Brand:
Daikin
| Category:
Inverter
| Size: 24 MB
Table of Contents
6 Wiring Diagrams 1
5
System Outline
3
Table of Contents
5
About this Manual
11
Service Tools
17
What Is in this Chapter?
25
RZQ71: Outlook and Dimensions
26
RZQ100 and RZQ125: Outlook and Dimensions
28
RZQ71, RZQ100 and RZQ125: Installation and Service Space
30
Part 1 1
33
What Is in this Chapter?
33
General Outline
34
Fcq35B7V1 ~ Fcq71B7V3B
34
Fcq100~125B7V3B
36
Ffq35~60Bv1B
38
Fbq35B7V1 & Fbq50B7V1
40
Fbq60B7V1 & Fbq71B7V3B
42
Fbq100B7V3B & Fbq125B7V3B
44
Fdq125B7V3B
46
Fhq35Buv1 & Fhq50Buv1
48
Fhq60Buv1 & Fhq71Buv1B
50
Fhq100Buv1B
52
Fhq125Buv1B
54
Fuq71Buv1B
56
Fuq100~125Buv1B
58
Faq71Buv1B
60
Faq100Buv1B
62
Part 1 1
65
What Is in this Chapter?
65
RZQ71, RZQ100 and RZQ125
66
Indoor Units
67
Specifications
67
Electrical Specifications
67
Electrical Data
67
Specifications
68
Fcq
69
Ffq
70
Fbq
71
Fdq
72
Technical Specifications
72
Fhq
73
Fuq
74
Faq
75
Part 1 1
77
What Is in this Chapter?
77
Pair System
78
Functional Diagram
80
Twin System
80
Triple System
82
Double Twin System
83
Indoor Piping
84
Pipe Connection Diameters
86
Re-Using Existing Field Piping
87
Piping Components
93
Part 1 1
95
What Is in this Chapter?
95
Switch Box Layout
96
Rzq71B7V3B
96
Rzq100B7V3B
97
PCB Layout
98
Fcq35B7V1 ~ Fcq71B7V3B
98
Fcq100~125B7V3B
99
Ffq35~60Bv1B
100
Fbq35B7V1 ~ Fbq125B7V3B
101
Fdq125B7V3B
102
Fhq35Buv1 ~ Fhq125Buv1B
103
Fuq71~125Buv1B
104
Faq71Buv1B
105
Faq100Buv1B
106
Part 1 1
107
Wiring Diagrams
107
What Is in this Chapter
107
Rzq71B7V3B
108
Wiring Diagram
108
Rzq100~125B7V3B
109
Wiring Diagram
109
Fcq35~60B7V1
110
Fcq71~125B7V3B
111
Ffq35~60Bv1B
112
Fbq35~60B7V1
113
Fbq71B7V3B
114
Fbq100~125B7V3B
115
Fdq125B7V3B
116
Fhq35~60Buv1
117
Fhq71~125Buv1B
118
Fuq71~125Buv1B
119
Faq71Buv1B
120
Faq100Buv1B
121
PCB Layout
123
What Is in this Chapter
123
Rzq71B7V3B
124
Rzq100B7V3B
126
Fcq35~60B7V1
128
Fcq71~125B7V3B
129
Ffq35~60Bv1B
130
Fbq35~60B7V1
131
Fbq100~125B7V3B
132
Fdq125B7V3B
133
Fhq35~60Buv1
134
Fhq71~125Buv1B
135
Fuq71~125Buv1B
136
Faq71Buv1B
137
Faq100Buv1B
138
Functional Description
139
What Is in this Chapter
141
Functions of Thermistors
142
Forced Operating Mode (Emergency Operation)
144
Outdoor Unit Identification Function
146
Simulated Operation Function
147
Restart Standby
148
Automatic Restart
149
Using Conditions for Remote Controller Thermostat
150
Forced Thermostat off
151
Test Run Control
152
4-Way Valve Control
153
Pump down Residual Operation
154
Pump down Operation
155
Defrost Operation
156
Freeze Prevention Function
158
PMV Control
159
Preheating Operation Control
160
Crankcase Heater Control
161
Part 2 1 2
163
Indoor Unit Functional Concept
163
What Is in this Chapter
163
Thermostat Control
164
Drain Pump Control
165
Condensation Avoidance Control
167
Draft Avoidance Control 1
168
Draft Avoidance Control
169
Fan and Flap Operations
170
Indoor Unit Fan Control
171
Outdoor Unit Functional Concept
173
What Is in this Chapter
173
Function Outline
174
Frequency Regulating Functions
177
Starting Frequency Control
178
General Frequency Control
181
Low Pressure Protection Control
183
High Pressure Protection Control
184
Discharge Pipe Temperature Control
185
Suction Pipe Superheat Protection Control (Heating Mode)
186
Inverter Current Protection Control
187
Input Current Control
188
Inverter Cooling Fin Temperature Control
189
Pressure Difference Control
190
Oil Recovery Operation
192
Expansion Valve Regulating Functions
193
Outdoor Unit Fan Speed Control
197
What Is in this Chapter?
203
General Troubleshooting Flowchart
204
Overview of General Problems
205
Procedure of Self-Diagnosis by Remote Controller
224
Fault-Diagnosis by Wired Remote Controller
225
Fault-Diagnosis by Wireless Remote Controller
226
Overview of Error Codes
230
Troubleshooting by Led Indications
232
Troubleshooting by Remote Controller Display / Led Display
234
Overview of the Outdoor Safety Devices
237
Overview of the Indoor Safety Devices
238
What Is in this Chapter
239
Malfunctioning Indoor PCB
240
Malfunction of Drain Water Level System
241
Malfunctioning Drain System
244
Indoor Unit Fan Motor Lock
246
Malfunctioning Capacity Setting
248
Thermistor Abnormality
250
Malfunctioning Remote Controller Air Thermistor
252
Part 3 1
253
What Is in this Chapter
253
Actuation of Protection Device
254
Failure of Outdoor Unit PC Board
255
Abnormal High Pressure (Detected by the HPS) (E3)
256
Actuation of Low Pressure Sensor
258
Compressor Motor Lock
260
Malfunction of Outdoor Unit Fan Motor
262
Malfunction of Outdoor Unit Fan Motor (E7)
262
Malfunction of Electronic Expansion Valve
263
Malfunction of Electronic Expansion Valve (E9)
263
Malfunctioning in Discharge Pipe Temperature
265
Malfunctioning in Discharge Pipe Temperature (F3)
265
Malfunctioning HPS System
267
Malfunctioning HPS System (H3)
267
Malfunction of Outdoor Fan Motor Signal
268
Malfunction of Outdoor Fan Motor Signal (H7)
268
Malfunction of Thermistor System
269
Malfunction of Thermistor System (H9, J3, J5, J6)
269
Malfunction of Suction Pipe Pressure Sensor
270
Malfunction of Suction Pipe Pressure Sensor (JC)
270
Radiation Fin Temperature Increased
271
Radiation Fin Temperature Increased (L4)
271
DC Output Overcurrent (Instantaneous)
272
DC Output Overcurrent (Instantaneous) (L5)
272
Electronic Thermal (Time Lag)
274
Electronic Thermal (Time Lag) (L8)
274
Stall Prevention (Time Lag)
276
Stall Prevention (Time Lag) (L9)
276
Malfunction of Transmission System
278
Open Phase
280
Malfunction of Radiator Fin Temperature Thermistor
282
Failure of Capacity Setting
284
Gas Shortage (Malfunction)
285
Abnormal Power Supply Voltage
286
Error Codes: System Malfunctions
289
What Is in this Chapter
289
Malfunction of Transmission between Indoor and Outdoor Unit
289
Malfunction of Transmission between Indoor Unit and Remote Controller
289
Malfunction of Transmission between MAIN Remote Controller
293
And SUB Remote Controller (U8)
293
Malfunctioning Field Setting Switch
294
Centralized Address Setting Error
296
Part 3 1
297
Additional Checks for Troubleshooting
297
What Is in this Chapter
297
Indoor Unit: Checking the Fan Motor Hall IC
298
Indoor Unit: Checking the Power Supply Wave Form
299
Outdoor Unit: Checking the Installation Condition
300
Outdoor Unit: Checking the Expansion Valve
301
Checking the Thermistors
302
Resistance Conversion Table (Ambient, Coil, Fin)
303
R3T: Resistance Conversion Table (Discharge Pipe Sensor)
304
Evaluation of Abnormal High Pressure
305
Evaluation of Abnormal Low Pressure
306
Checks
307
What Is in this Chapter?
315
Test Run Checks
316
Setting the Wireless Remote Controller
317
Part 4 1
321
What Is in this Chapter?
321
Topic
322
How to Change the Field Settings with the Wired Remote Controller
322
How to Change the Field Settings with the Wireless Remote Controller
324
Overview of the Field Settings on the Indoor Units
325
Overview of the Factory Settings on the Indoor Units
326
Setting the Ceiling Height
327
Setting the Filter Counter
328
MAIN/SUB Setting When Using Two Remote Controllers
329
Setting the Centralized Group no
330
The Field Setting Levels
332
Overview of the Field Settings on the Outdoor Units
335
Overview of the Factory Settings on the Outdoor Units
337
Silent Operation
338
I-Demand Function
340
Setting for Low Humidity Application
342
Defrost Start Setting
348
3 Test Run and Operation Data
349
General Operation Data
350
Operation Range
353
1.2 Rzq71~125B7V3B 1
358
Removal of Outside Panels
359
Removal of Propeller Fan and Fan Motor
360
Removal of Switch Box
361
Removal of PC Board Ass'y
363
Removal of Low Pressure Sensor, Electronic Expansion Valve, and Others
366
Removal of Thermistor
367
Removal of Four Way Valve
368
Removal of Compressor
369
Disassembly and Maintenance: Outdoor Units
370
Part 5 1
371
What Is in this Chapter
371
Topic
372
Fcq35B7V1 ~ Fcq71B7V3B
372
Fcq100~125B7V3B
374
Fbq35~50B7V1
376
Fbq60B7V1 ~ Fbq71B7V3B
378
Fbq100~125B7V3B
380
Fdq125B7V3B
382
2.8 Ffq35~60Bv1B 1
384
Removal of Air Filter
386
Removal of Decoration Panel
388
Removal of Horizontal Vane
391
Removal of Swing Motor
393
Removal of Switch Box
395
Removal of Fan Rotor and Fan Motor
397
Removal of Drain Pan
400
Removal of Drain Pump
401
2.8.10 Installation of Drain Pump
403
2.8.11 Replacement of Heat Exchanger Thermistor
406
2.8.12 Replacement of Heat Exchanger
408
2.8.13 Replacement of PC Board
414
2.8.14 Replacement of Receiver Section of Wireless Remote Controller
418
2.9 Fhq35~125Buv1(B) 1
421
Topic
422
Removal of Air Filter and Suction Grille
422
Removal of Electrical Parts and PC Boards
424
Removal of Horizontal Blade
427
Removal of Fan Rotor and Fan Motor
428
Removal of Fan Bearing
431
Removal of Bottom Panel and Drain Pan
433
Removal of Swing Motor
435
Removal of Fan
440
Removal of Air Flow Control Blade
451
Removal of Air Filter and Front Panel
454
Removal of Front Grille
456
Removal of the Horizontal Blade and Vertical Blade
457
Removal of Electrical Box
459
Removal of Fan Motor and Fan Rotor
461
Removal of Air Swing Motor
462
Drain Hose Piping to the Left
463
Removal of Electrical Parts Box
467
Removal of Pc Board
468
Removal of Swing Louvre Unit
469
Removal of Fan Rotor
475
Advertisement
Advertisement
Related Products
Daikin RXYQ12MY1
Daikin RXYQ40MY1
Daikin RXYQ28MY1
Daikin RSEYP8KJY1
Daikin RSXY5GY1
Daikin RSXY8GY1
Daikin RSXY5HTAL
Daikin RX24KY1
Daikin RX10MY1
Daikin RXQ48AMYM
Daikin Categories
Air Conditioner
Heat Pump
Chiller
Remote Control
Air Handlers
More Daikin Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL