Ipmi Submenu - Fujitsu PRIMERGY RX200 S4 User Manual

Hide thumbs Also See for PRIMERGY RX200 S4:
Table of Contents

Advertisement

Chapter 7 Configuring Hardware and Utilities

7.2.10 IPMI Submenu

This submenu appears when selecting [IPMI] from the [Advanced] menu.
Use this submenu to configure the integrated Remote Management Controller (iRMC) settings.
Advanced
SEL Load
Clear System Event Log:
Event Log Full Mode:
iRMC Time Sync:
>
System Event Log
SDRR Browser
>
LAN Settings
>
Item
SEL Load
Clear System Event Log
Event Log Full Mode
iRMC Time Sync
System Event Log
SDRR Browser
LAN Settings
190
PhoenixBIOS Setup Utility
IPMI
**%
[Disabled]
[Overwrite]
[Enabled]
table: Items on the IPMI Submenu
Setting
Displays the percentage of the System Event Log (SEL) stored.
• Disabled (Initial value)
• Enabled
Overwrite (Unchangeable)
Enabled (Unchangeable)
Displays the content of the SEL.
The system event logs referable in this submenu are for reference only. For details
on the system event logs, see "8.3 System Event Log" ( p.221).
Displays data for each sensor.
Sets the LAN when remote controlled by the RemoteControlService.
"
LAN Settings submenu" (p.191)
Item Specific Help
Description
Sets whether or not to delete the logs stored in the
System Event Log (SEL).
Configures the log settings when the SEL becomes
full.
Sets whether or not to synchronize the internal
timer of the integrated Remote Management
Controller (iRMC) with the system time.