Installable Cpus And Notes; How To Install A Cpu - Fujitsu PRIMERGY RX200 S4 User Manual

Hide thumbs Also See for PRIMERGY RX200 S4:
Table of Contents

Advertisement

6.3.2 Installable CPUs and Notes

Installable CPUs
The following types of CPUs can be installed on this server. When installing an optional CPU, the two
CPUs must have the same product name (same frequency/cache size).
Processor Xeon E5205 (1.86GHz)
Processor Xeon X5260 (3.33GHz)
Processor Xeon E5405 (2GHz)
Processor Xeon E5420 (2.50GHz)
Processor Xeon X5460 (3.16GHz)
Processor Xeon L5410 (2.33GHz)
Processor Xeon X5270 (3.50GHz)
Processor Xeon X5470 (3.33GHz)
Package
Before installing an optional CPU, see "Appendix B.1 CPU" ( p.246) to check the packaged contents.

6.3.3 How to Install a CPU

This section explains how to install a CPU.
1
Turn off the power and all peripheral devices, and pull the server out from the
rack to remove the top cover.
"6.2 Attaching/Removing the Top Cover" (p.132)
2
Touch a metal part of the server to discharge static electricity.
table: List of installable CPUs
Product name
PRIMERGY RX200 S4 User's Guide
Product ID
PG-FG41G
PG-FG41H
PG-FG41J
PG-FG41K
PG-FG41L
PG-FG41P
PG-FG41N
PG-FG41M
135

Advertisement

Table of Contents
loading

Table of Contents