Chapter 7 Configuring Hardware and Utilities
Item
Action
Timeout Value
ASR&R Boot Delay
Power Cycle Delay
Boot Retry Counter
Temperature Monitoring
Memory Scrubbing
CPU Status
Memory Status
PCI Status
Console Redirection
194
table: Items on the Server Menu
Setting
• Continue
• Reset (Initial value)
• Power Cycle
• 0 (Initial value)
• 1 to 100
2 (Unchangeable)
7 (Unchangeable)
• 3 (Initial value)
• 0 to 7
Disabled (Unchangeable)
Enabled (Unchangeable)
Sets whether or not to allow the use of the installed CPU.
"7.2.13 CPU Status Submenu" (p.195)
Sets whether or not to allow the use of the installed memory modules.
"7.2.14 Memory Status Submenu" (p.196)
Sets whether or not to allow the use of the installed PCI card.
"7.2.15 PCI Status Submenu" (p.197)
Configures detailed settings for console redirection.
"7.2.16 Console Redirection Submenu" (p.198)
Description
Sets the action to take if OS boot monitoring times
out.
Sets the timeout period. If the [O/S boot Timeout] is
set to "Enabled" and the startup of the OS does not
complete within the period set here, the system
automatically restarts.
Sets the time of reboot of the Automatic Server
Reconfiguration & Restart (ASR&R) function.
Sets the time until the server is turned on again after
it is turned off.
Sets the maximum number of retries for booting the
OS from 1 to 7.
Each retry decreases the count value by one.
Sets whether or not to turn the power off when the
temperature is abnormal.
Sets whether or not to correct errors in memory
domains currently unused by the OS, or by
application programs.