Server Management Tools Error Messages - Fujitsu PRIMERGY RX200 S4 User Manual

Hide thumbs Also See for PRIMERGY RX200 S4:
Table of Contents

Advertisement

Message
iRMC reports sensor status: CRITICAL
DIMM-*D (*: 1 to 3)
iRMC reports sensor status: WARNING
DIMM-*D (*: 1 to 3)
iRMC reports sensor status: CRITICAL PCI
Slot* (*: 1 to 3)
iRMC reports sensor status: WARNING PCI
Slot* (*: 1 to 3)
iRMC reports sensor status: CRITICAL CPU*
(*: 1 or 2)
iRMC reports sensor status: WARNING
CPU* (*: 1 or 2))

Server Management Tools error messages

The following error messages may appear while executing Server Management Tools. Perform the
corresponding resolution listed in the table. If messages other than the following are displayed, contact
an office listed in the "Contact Information" of the "Start Guide".
Message
Write protect error writing drive A.
Abort, Retry, Fail?
Not ready writing drive A.
Abort, Retry, Fail?
ERROR:Fail to create data file.
ERROR:Fail to write 1st CMOS data into data file. nn
ERROR:Fail to write 2nd CMOS data into data file. nn
ERROR:Fail to write ESCD data into the data file. nn
ERROR:Fail to write SEEPROM data into the data file.
nn
ERROR:Fail to open data file.
ERROR:Fail to write 1st CMOS data into system. nn
ERROR:Fail to write 2nd CMOS data into system file.
nn
ERROR:Fail to write ESCD data into system file. nn
ERROR:Fail to write SEEPROM data into system. nn
table: List of POST error messages
Memory *D error. Replace the displayed memory pair. If the
message still appears, the baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
The PCI slot is abnormal. Check the error log and replace the
PCI card. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
The CPU is abnormal. Check the error log and replace the faulty
CPU. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".
table: List of Server Management Tools error messages
PRIMERGY RX200 S4 User's Guide
Description
Description
The inserted floppy disk is write-protected. Disable the
write-protect, and then press the [R] key.
The floppy disk is not inserted. Insert the proper floppy
disk ("Server Management Tools" floppy disk), and
then press the [R] key.
The following are possible causes. Check the floppy
disk status again.
• The floppy disk is write-protected. Disable the
write-protect and retry.
• The floppy disk is not inserted. Insert the proper
floppy disk, and then retry.
• The floppy disk contains abnormal contents. Create
the "Server Management Tools" floppy disk again. If
this occurred while recovering BIOS information,
configure the information using the BIOS Setup
Utility. Then store the BIOS information.
The file for recovering the BIOS information does not
exist on this floppy disk. Insert the floppy disk on
which the BIOS information was stored, and then retry.
The following are possible causes. Check the floppy
disk status again.
• The floppy disk is not inserted. Insert the proper
floppy disk, and then retry.
• A different model or an unsupported version of
BIOS information. Insert the proper floppy disk, and
then retry.
• The floppy disk contains abnormal contents. Create
the "Server Management Tools" floppy disk again. If
this occurred while recovering BIOS information,
configure the information using the BIOS Setup
Utility. Then store the BIOS information.
213

Advertisement

Table of Contents
loading

Table of Contents